Related Experiment Video
Updated: Aug 7, 2025

Screening of Axonal Degeneration in Carpal Tunnel Syndrome Using Ultrasonography and Nerve Conduction Studies
Published on: January 11, 2019
Computed tomography scan to diagnose abducens nerve palsy cases with superior-compartment atrophy
Arash Mirmohammadsadeghi1, Shabnam Keivani1, Shervin Sharifkashani1
1Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran.
Purpose:
To use orbital computed tomography (CT) to explore the proportion of superior-compartment lateral rectus muscle atrophy in abducens nerve palsy and its relationship with clinical findings.
Methods:
Twenty-two patients with isolated unilateral abducens nerve palsy were enrolled. Orbital CT scans of all patients were acquired. All measurements were performed in two ways for normal and paretic lateral rectus muscles: posterior volume (mm3) and maximal cross-section area (mm2). These variables were also measured separately in the superior and inferior 40% of the muscle. Primary position esotropia and amount of abduction limitation was also recorded.
Results:
The mean deviation was 23.4Δ ± 12.1Δ (range, 0Δ-50Δ); the mean limitation of abduction, -2.7 ± 1.3 (range, -1 to -5). Seven cases (31.8%) showed the gross morphologic characteristics of superior-compartment atrophy. In these 7 cases, the mean percentage of atrophy in posterior volume and in maximal cross-section was significantly greater in the superior compartment than the inferior compartment (P = 0.02 for both). The mean limitation of abduction in these 7 cases (-1.7 ± 0.9; range, -1 to -3) was significantly lower than in other cases (-3.1 ± 1.3, range, -1 to -5 [P = 0.02]).
Conclusions:
In our study cohort, a subgroup of abducens nerve palsy cases demonstrated evidence of superior portion lateral rectus atrophy on orbital CT. The superior-compartment-atrophy group had both a smaller primary gaze esotropia and a smaller abduction deficit, providing evidence that compartmental atrophy should be considered in patients with partially retained lateral rectus function.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Cranial Nerves: Types Part I
Olfactory Nerve (Cranial Nerve I)
The olfactory nerve, or cranial nerve I, is unique as it is purely sensory and dedicated to the sense of smell. This nerve originates in the olfactory epithelium of the...

