A model-free method for mass spectrometer response correction.

B E Shykoff1, H T Swanson

  • 1Department of Physiology, State University of New York, Buffalo 14214.

Journal of Applied Physiology (Bethesda, Md. : 1985)
|November 1, 1987
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Pulmonary effects of submerged exercise while breathing 140 kPa oxygen.

Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc·2009
Same author

Pulmonary effects of submerged oxygen breathing in resting divers: repeated exposures to 140 kPa.

Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc·2008
Same author

Simultaneous determination of the accuracy and precision of closed-circuit cardiac output rebreathing techniques.

Journal of applied physiology (Bethesda, Md. : 1985)·2007
Same author

Pulmonary effects of submerged oxygen breathing: 4-, 6-, and 8-hour dives at 140 kPa.

Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc·2006
Same author

Stability of pulmonary function in U.S. Navy divers.

Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc·2005
Same author

Revised one-step method for determination of cardiac output.

Respiratory physiology & neurobiology·2004
Same journal

Change in Neutrophil-to-Lymphocyte Ratio after acute and chronic exercise: A Systematic Review and Meta-Analysis.

Journal of applied physiology (Bethesda, Md. : 1985)·2026
Same journal

Ankylosing spondylitis and muscle sympathetic nerve activity: a case study.

Journal of applied physiology (Bethesda, Md. : 1985)·2026
Same journal

Intracranial vasomotor and blood flow responses to light intensity aerobic exercise in young adults: a 4D flow MRI study.

Journal of applied physiology (Bethesda, Md. : 1985)·2026
Same journal

Comparative assessments of the COSMED adaptive mixing chamber vs. breath-by-breath methods for oxygen uptake measurements in recreationally active adults.

Journal of applied physiology (Bethesda, Md. : 1985)·2026
Same journal

Can we assess exercise metabolism from skin? Metabolomic profiles in skin dialysate collected during exercise.

Journal of applied physiology (Bethesda, Md. : 1985)·2026
Same journal

Characterization of intracranial pressure variations in ventricular and subarachnoid spaces of the rat brain.

Journal of applied physiology (Bethesda, Md. : 1985)·2026
See all related articles

A novel deconvolution filter corrects mass spectrometer signal distortions without a specific model. This method significantly reduces errors in O2 and CO2 measurements, even with noisy data.

Area of Science:

  • Analytical Chemistry
  • Instrumental Analysis

Background:

  • Mass spectrometry data can suffer from response-time distortion.
  • Accurate signal correction is crucial for reliable quantitative analysis.

Purpose of the Study:

  • To develop a model-independent method for correcting mass spectrometer output signals.
  • To improve the accuracy of gas exchange measurements (O2 consumption, CO2 production).

Main Methods:

  • Determining system delay using cross-correlation of step changes and responses.
  • Generating a digital deconvolution filter from step response data via regression.
  • Applying the filter and delay to correct corrupted data.

Main Results:

  • Significantly reduced mean squared error compared to second-order model correction.

Related Experiment Videos

  • Restored O2 consumption and CO2 production values close to uncorrupted levels.
  • Correction remains effective with up to 0.5% random noise in the response signal.
  • Conclusions:

    • The developed deconvolution filter effectively corrects response-time distortion in mass spectrometer signals.
    • This method offers a robust and accurate approach for quantitative analysis, particularly for gas exchange measurements.
    • The technique is adaptable and resilient to moderate levels of noise.