Related Experiment Video
Updated: Jul 14, 2026

Determination of Cardiac Output in a Porcine Model for Ex Vivo Pulmonary Perfusion
Published on: June 28, 2024
Simultaneous determination of the accuracy and precision of closed-circuit cardiac output rebreathing techniques
S S Jarvis1, B D Levine, G K Prisk
1Department of Kinesiology, Pennsylvania State University, University Park, Pennsylvania 16802, USA.
Abstract:
Foreign and soluble gas rebreathing methods are attractive for determining cardiac output (Q(c)) because they incur less risk than traditional invasive methods such as direct Fick and thermodilution. We compared simultaneously obtained Q(c) measurements during rest and exercise to assess the accuracy and precision of several rebreathing methods. Q(c) measurements were obtained during rest (supine and standing) and stationary cycling (submaximal and maximal) in 13 men and 1 woman (age: 24 +/- 7 yr; height: 178 +/- 5 cm; weight: 78 +/- 13 kg; Vo(2max): 45.1 +/- 9.4 ml.kg(-1).min(-1); mean +/- SD) using one-N(2)O, four-C(2)H(2), one-CO(2) (single-step) rebreathing technique, and two criterion methods (direct Fick and thermodilution). CO(2) rebreathing overestimated Q(c) compared with the criterion methods (supine: 8.1 +/- 2.0 vs. 6.4 +/- 1.6 and 7.2 +/- 1.2 l/min, respectively; maximal exercise: 27.0 +/- 6.0 vs. 24.0 +/- 3.9 and 23.3 +/- 3.8 l/min). C(2)H(2) and N(2)O rebreathing techniques tended to underestimate Q(c) (range: 6.6-7.3 l/min for supine rest; range: 16.0-19.1 l/min for maximal exercise). Bartlett's test indicated variance heterogeneity among the methods (P < 0.05), where CO(2) rebreathing consistently demonstrated larger variance. At rest, most means from the noninvasive techniques were +/-10% of direct Fick and thermodilution. During exercise, all methods fell outside the +/-10% range, except for CO(2) rebreathing. Thus the CO(2) rebreathing method was accurate over a wider range (rest through maximal exercise), but was less precise. We conclude that foreign gas rebreathing can provide reasonable Q(c) estimates with fewer repeat trials during resting conditions. During exercise, these methods remain precise but tend to underestimate Q(c). Single-step CO(2) rebreathing may be successfully employed over a wider range but with more measurements needed to overcome the larger variability.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: