Updated: Aug 6, 2025

Retzius-Sparing Robot-Assisted Radical Prostatectomy
12:10

Retzius-Sparing Robot-Assisted Radical Prostatectomy

Published on: May 19, 2022

7.9K

SENHANCE ROBOTIC RADICAL PROSTATECTOMY.

Tomislav Kuliš1,2, Tvrtko Hudolin1,2, Luka Penezić1

  • 1Department of Urology, University Hospital Center Zagreb, Zagreb, Croatia.

Acta Clinica Croatica
|March 20, 2023
PubMed
Summary

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Closely similar tacrolimus morning troughs and graft function across the recipients' common <i>ABCB1</i> polymorphisms (<i>c.2677G>T/A</i>, <i>c.1236C>T</i>, <i>c.3435C>T</i>) early after renal transplantation.

Pharmacogenomics·2026
Same author

Adoption and Efficiency of an Anesthesia Information Management System: Evaluation of Workflow Integration in Perioperative Care.

Healthcare (Basel, Switzerland)·2026
Same author

Repressive regulatory function of seryl-tRNA synthetase on VEGFA gene expression is impaired in renal cell carcinoma.

Croatian medical journal·2026
Same author

High feasibility and safety of office-based transurethral laser ablation for recurrent non-muscle invasive bladder cancer: a single-center experience.

Frontiers in oncology·2026
Same author

Biomineralization of Glucose Oxidase from <i>Aspergillus niger</i> in ZIF-zni for Enhanced Biocatalytic Performance.

Bioengineering (Basel, Switzerland)·2026
Same author

Micro-UltraSound In Cancer - Active Surveillance (MUSIC-AS): A paired, prospective, non-inferiority trial comparing micro-ultrasound and multiparametric MRI at confirmatory biopsy.

Contemporary clinical trials communications·2026

The Senhance robotic platform is a new, feasible, and safe option for robotic radical prostatectomy in localized prostate cancer treatment. Studies show comparable operative times and blood loss to existing methods.

Area of Science:

  • Urology
  • Surgical Technology
  • Oncology

Background:

  • Robotic radical prostatectomy is a standard treatment for localized prostate cancer.
  • Historically, a single robotic platform dominated the field.
  • The Senhance system represents a novel alternative for robotic surgery.

Purpose of the Study:

  • To review the initial clinical experience with the Senhance robotic platform for radical prostatectomy.
  • To assess the feasibility, safety, and oncological outcomes of the Senhance system.

Main Methods:

  • Systematic literature search of PubMed and Scopus databases using the term "Senhance".
  • Inclusion of prospective case series reporting operative data and oncological outcomes.
  • Analysis of data from two studies involving 234 patients.
Keywords:
Robotic prostatectomy: Prostate cancerSenhance

More Related Videos

Robot-assisted Total Mesorectal Excision and Lateral Pelvic Lymph Node Dissection for Locally Advanced Middle-low Rectal Cancer
12:45

Robot-assisted Total Mesorectal Excision and Lateral Pelvic Lymph Node Dissection for Locally Advanced Middle-low Rectal Cancer

Published on: February 12, 2022

5.8K
Author Spotlight: Cutting-Edge Robotic Heller Myotomy Protocol for Treatment of Achalasia
09:46

Author Spotlight: Cutting-Edge Robotic Heller Myotomy Protocol for Treatment of Achalasia

Published on: February 16, 2024

750

Related Experiment Videos

Last Updated: Aug 6, 2025

Retzius-Sparing Robot-Assisted Radical Prostatectomy
12:10

Retzius-Sparing Robot-Assisted Radical Prostatectomy

Published on: May 19, 2022

7.9K
Robot-assisted Total Mesorectal Excision and Lateral Pelvic Lymph Node Dissection for Locally Advanced Middle-low Rectal Cancer
12:45

Robot-assisted Total Mesorectal Excision and Lateral Pelvic Lymph Node Dissection for Locally Advanced Middle-low Rectal Cancer

Published on: February 12, 2022

5.8K
Author Spotlight: Cutting-Edge Robotic Heller Myotomy Protocol for Treatment of Achalasia
09:46

Author Spotlight: Cutting-Edge Robotic Heller Myotomy Protocol for Treatment of Achalasia

Published on: February 16, 2024

750

Main Results:

  • Average operative time ranged from 180 to 195 minutes.
  • Estimated blood loss was between 250 and 300 mL.
  • Reported complications included 3 Clavien-Dindo grade III and 1 grade IV.

Conclusions:

  • The Senhance robotic platform is a feasible and safe option for radical prostatectomy.
  • Initial outcomes suggest comparable performance to existing laparoscopic approaches.