Related Experiment Video
Updated: Aug 6, 2025

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
The experience of auditory implant recipients undergoing magnetic resonance imaging: Factors associated with pain
Matthew E Smith1, Daniel J Moualed2, Simon R Freeman1
1Department of Otolaryngology, The Richard Ramsden Centre for Hearing Implants, Manchester Royal Infirmary, Manchester, UK.
Objective:
Many patients with cochlear implants (CI) and auditory brainstem implants (ABI) require magnetic resonance imaging (MRI) following implantation. This study explores the patient experience of MRI, identifying factors associated with pain, and the effect of interventions designed to enhance comfort and safety.
Methods:
A prospective observational case series from a tertiary referral unit. Tight head bandaging ± local anaesthetic injection (devices with non-MRI-compatible magnets) or observation alone (implants with MRI-compatible magnets) were employed for 1.5 T MRI of consecutive adult patients with CI or ABI without magnet removal. Pain was recorded via visual analogue scale (1 = no pain, 5 = extreme pain) at three time points; (1) baseline, (2) head bandage applied (3) during scanning. Patient age, device type, body area imaged and total scan time were recorded as variables, alongside adverse events.
Results:
Data were collected for 227 MRI scans (34 patients with ABI, 32 with CI). In patients managed with bandaging, pain score after bandaging but prior to scanning (median 2.2) did not differ from pain during scanning (2.1), but both were significantly higher than baseline (1.4, both P ≤ 0.001). Scanning areas other than the head/cervical spine was associated with higher pain scores (P = 0.036). Pain during MRI differed between different manufacturers implants (P ≤ 0.001). Adverse events occurred in 8/227 scans (3.5%), none occurring with devices containing an MRI-compatible magnet.
Conclusion:
MRI scanning with auditory implant magnets in situ is safe and well tolerated by patients.
More Related Videos
06:54Author Spotlight: Advancements in Impedance Monitoring for Cochlear Implant Surgery
Published on: August 4, 2023
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging