A radiofrequency coil for infants and toddlers

Kyle M Gilbert1,2, Emily S Nichols3,4, Joseph S Gati1,2

  • 1Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, Ontario, Canada.

NMR in Biomedicine
|March 20, 2023
PubMed

Insights

This study introduces an adaptable radiofrequency (RF) coil designed for infant and toddler brain MRI. The new coil improves signal-to-noise ratio (SNR) and motion reduction, enabling sedation-free scans with enhanced image quality for pediatric neuroimaging.

Area of Science:

  • Medical Imaging
  • Biomedical Engineering
  • Pediatric Radiology

Background:

  • Pediatric brain MRI presents challenges due to varying head sizes and motion in infants and toddlers.
  • Existing adult radiofrequency (RF) coils are suboptimal for pediatric neuroimaging, impacting image quality and scan efficiency.
  • Effective immobilization and motion correction techniques are crucial for successful pediatric MRI.

Purpose of the Study:

  • To develop and evaluate an adaptable RF coil specifically designed for pediatric brain MRI, accommodating a wide range of head sizes from infancy to early childhood.
  • To improve signal-to-noise ratio (SNR) and facilitate motion mitigation in pediatric neuroimaging.
  • To enable high-quality, sedation-free brain MRI scans in infants and toddlers.

Main Methods:

  • Designed a novel RF coil with adjustable elements to fit head sizes from 3-month-old infants to 3-year-old toddlers.
  • Optimized coil geometry for improved SNR and inherent head immobilization.
  • Integrated features for unimpeded facial view to allow for potential motion-tracking system integration.

Main Results:

  • The pediatric RF coil demonstrated higher SNR across most brain regions compared to standard adult coils, with over twofold improvement in peripheral areas.
  • Achieved fourfold acceleration rates in each Cartesian direction, enabling shorter scan times.
  • The coil's design, combined with adjustable geometry and potential motion-tracking, significantly reduced motion artifacts and allowed for sedation-free scanning.

Conclusions:

  • The developed adaptable pediatric RF coil significantly enhances image quality and scan efficiency for infant and toddler brain MRI.
  • This technology offers a promising platform for high-resolution, sedation-free pediatric neuroimaging in both research and clinical settings.
  • Improved SNR and motion control are key to advancing pediatric neuroimaging capabilities.

Related Concept Videos

Temperature Measurement Sites01:14

Temperature Measurement Sites

A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.9K
Generating Electromagnetic Radiations01:10

Generating Electromagnetic Radiations

The German physicist Heinrich Hertz (1857–1894) was the first to generate and detect certain types of electromagnetic waves in the laboratory. Starting in 1887, he performed a series of experiments that confirmed the existence of electromagnetic waves and verified that they travel at the speed of light. Hertz used an alternating-current RLC (resistor-inductor-capacitor) circuit that resonated at a known frequency and connected it to a loop of wire. High voltages induced across the gap in...
3.3K
Electromagnetic Fields01:30

Electromagnetic Fields

Electric fields generated by static charges, often referred to as electrostatic fields, are characteristically different from electric fields created by time-varying magnetic fields. While the former is a conservative field, implying that no net work is done on a test charge if it goes around in a complete loop in the field, the latter is, by definition, not a conservative field; net work is done, and it is proportional to the rate of change of magnetic flux.
However, the observation of...
2.2K