Quality improvement project to reduce unplanned extubations in a paediatric intensive care unit
Joyce Caroline Dinelli Ferreira1, Milena Siciliano Nascimento2, Simone Brandi3
1Departamento de Qualidade e Segurança, Hospital Israelita Albert Einstein, São Paulo, Brazil.
Background:
Unplanned extubations are recurrent adverse events in mechanically ventilated children and have been the focus of quality and safety improvement in paediatric intensive care units (ICUs).
Local Problem:
To reduce the rate of unplanned extubation in the paediatric ICU by 66% (from 2.02 to 0.7).
Methods:
This is a quality improvement project that was conducted in a paediatric ICU of a private hospital at the quaternary level. All hospitalised patients who used invasive mechanical ventilation between October 2018 and August 2019 were included.
Interventions:
The project was based on the Improvement Model methodology of the Institute for Healthcare Improvement to implement change strategies. The main ideas of change were innovation in the endotracheal tube fixation model, evaluation of the endotracheal tube positioning, good practices of physical restraint, sedation monitoring, family education and engagement and checklist for prevention of unplanned extubation, with Plan-Do-Study-Act, the tool chosen to test and implement ideas for change.
Results:
The actions reduced the unplanned extubation rate to zero in our institution and sustained this result for a period of 2 years, totalling 743 days without any event. An estimate was made comparing cases with unplanned extubation and controls without the occurrence of this adverse event, which resulted in savings of R$955 096.65 (US$179 540.41) during the 2 years after the implementation of the improvement actions.
Conclusion:
The improvement project conducted in the 11-month period reduced the unplanned extubation rate to zero in our institution and sustained this result for a period of 743 days. Adherence to the new fixation model and the creation of a new restrictor model, which enabled the implementation of good practices of physical restraint were the ideas of change that had the greatest impact in achieving this result.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...