Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Aug 5, 2025

A Low Cost Setup for Behavioral Audiometry in Rodents
09:23

A Low Cost Setup for Behavioral Audiometry in Rodents

Published on: October 16, 2012

12.8K

Ambient Noise in Candidate Rooms for User-Operated Audiometry.

Christos Sidiras1,2, Jacob Nielsen2, Chris Bang Sørensen2

  • 1Clinical Psychoacoustics Lab, 3rd Psychiatry Department, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 54636 Thessaloniki, Greece.

Healthcare (Basel, Switzerland)
|March 29, 2023
PubMed
Summary

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Individuals with near-normal audiograms but perceived hearing difficulties can achieve aided outcomes on par with those of peers with mild hearing loss.

International journal of audiology·2026
Same author

Associations Between Neuropathy, Nephropathy and Hearing Loss in Individuals with Type 2 Diabetes.

Biomedicines·2026
Same author

Evaluating the user-operated audible contrast threshold test as a language-independent proxy of speech-in-noise perception.

International journal of audiology·2026
Same author

The Risk of Becoming a Cochlear Implant Non-user or Minimal-user in a Patient Cohort From Denmark 2010-2022.

Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology·2026
Same author

The Molecular Mechanism of PDE1 Regulation.

Cells·2025
Same author

Cross-Cultural Adaptation and Validation of the Danish Version of Inventory of Hyperacusis Symptoms.

Audiology research·2025
This summary is machine-generated.

Unsupervised audiometry in non-sound-treated rooms is feasible, provided noise levels meet standards. Circumaural headphones and potentially online noise monitoring are key for accessible hearing tests.

Area of Science:

  • Audiology
  • Acoustics
  • Biomedical Engineering

Background:

  • Hearing loss is a global health issue with limited access to professional care.
  • Developing accessible, unsupervised audiometric testing is crucial for widespread hearing healthcare.
  • Investigating alternative testing environments addresses accessibility barriers.

Purpose of the Study:

  • To assess the acoustic viability of inexpensive, non-sound-treated rooms for unsupervised audiometric testing.
  • To compare ambient noise levels in these rooms against established audiology standards.
  • To determine the feasibility of user-operated audiometry outside traditional sound-treated booths.

Main Methods:

  • Ambient noise measurements (10 min) were conducted in 20 non-sound-treated rooms (libraries, clinics).
Keywords:
acoustic environmentambient noisepure tone audiometrysound treateduser-operated

More Related Videos

Pupillometry to Assess Auditory Sensation in Guinea Pigs
09:25

Pupillometry to Assess Auditory Sensation in Guinea Pigs

Published on: January 6, 2023

1.8K
A Comparative Study of Drug Delivery Methods Targeted to the Mouse Inner Ear: Bullostomy Versus Transtympanic Injection
09:18

A Comparative Study of Drug Delivery Methods Targeted to the Mouse Inner Ear: Bullostomy Versus Transtympanic Injection

Published on: March 8, 2017

13.3K

Related Experiment Videos

Last Updated: Aug 5, 2025

A Low Cost Setup for Behavioral Audiometry in Rodents
09:23

A Low Cost Setup for Behavioral Audiometry in Rodents

Published on: October 16, 2012

12.8K
Pupillometry to Assess Auditory Sensation in Guinea Pigs
09:25

Pupillometry to Assess Auditory Sensation in Guinea Pigs

Published on: January 6, 2023

1.8K
A Comparative Study of Drug Delivery Methods Targeted to the Mouse Inner Ear: Bullostomy Versus Transtympanic Injection
09:18

A Comparative Study of Drug Delivery Methods Targeted to the Mouse Inner Ear: Bullostomy Versus Transtympanic Injection

Published on: March 8, 2017

13.3K
  • Noise data were compared against ISO 8231-1 Maximum Permissible Ambient (MPA) noise levels.
  • The acoustic attenuation provided by DD450 circumaural headphones was factored into the analysis.
  • Main Results:

    • Most non-sound-treated rooms met MPA levels, with violations primarily from transient sounds.
    • Ambient noise in non-sound-treated rooms showed greater fluctuations than in sound-treated rooms.
    • Noise violations predominantly occurred at low to mid-low frequencies.

    Conclusions:

    • User-operated audiometry in non-sound-treated rooms is possible under specific conditions.
    • Circumaural headphone attenuation is essential for maintaining acceptable noise levels.
    • Online systems for real-time noise assessment may enhance the reliability of unsupervised testing.