Related Experiment Video
Updated: Aug 5, 2025

In Situ Monitoring of the Accelerated Performance Degradation of Solar Cells and Modules: A Case Study for CuIn,GaSe2 Solar Cells
Published on: October 3, 2018
Development and Performance Evaluation of Photovoltaic (PV) Evaluation and Fault Detection System Using
Phuong-Truong Le1, Huan-Liang Tsai2, Phuong-Long Le1
1Faculty of Mechatronics and Electronics, Lac Hong University, 10, Huynh Van Nghe St., Buu Long, Bien Hoa 810000, Dong Nai, Vietnam.
Abstract:
This paper originally presents a photovoltaic (PV) evaluation and fault detection (PVEFD) system for PV applications based on the Internet of Things (IoT) technology. The PVEFD system consists of an STM32F103C8T6 chip with a 32-bit Arm Cortex-M3 reduced instruction set computer (RISC) and 12-bit resolution analog-to-digital converter (ADC) to measure important parameters of PV applications, such as solar irradiance as well as the back-surface cell temperature, operating voltage, and output current of PV devices. The measured data of irradiance as well as back-surface cell temperature and operating voltage of PV devices are then fed into a built-in PV model in the on-chip Arm Cortex-M3 RISC for hardware-in-the-loop (HIL) simulation to obtain the simulated output current and power of PV devices. The resulting data are transmitted to a cloud server for remote monitoring and automatic warning function through a Raspberry PI 3 module and WiFi network. The simulation results are compared with in-field measurement data from PV modules and displayed on a human-machine interface (HMI) and an Android app. The results of the study illustrated that the proposed system features high accuracy and sufficient confidence. Furthermore, the fault detection function through the built-in HIL simulation function in PV systems was validated. Therefore, the proposed system is a small, compact, and cost-effective HIL-on-chip machine for remote surveillance of PV power systems.
More Related Videos
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
09:00Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass ADG Fresnel Lens for Concentrating Photovoltaics
Published on: October 27, 2017
Related Concept Videos
Power System Three-Phase Short Circuits
Electrical Systems
To derive the transfer function, consider...
Control System Problem
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...