Related Experiment Video
Updated: Aug 4, 2025

Concurrent Quantification of Cellular and Extracellular Components of Biofilms
Published on: December 10, 2013
38. Effect of Chlorhexidine Rinsed Blood Contamination on Bond Strength of Brackets Bonded with Self-etch Primer- An
1Dr Nitu Dubey, Senior Lecturer, Department of Orthodontics and Dentofacial Orthopaedics, Mithila Minority Dental College and Hospital (MMDC&H), Darbhanga, Bihar, India;
Abstract:
The present invitro type of study has done to check the effect of blood contamination & chlorhexidine combination on the bond strength of brackets bonded with self-etch primer technique. The study consisted of ninety sound human upper premolars (extracted for orthodontic purpose) fixed in a self-cure acrylic block and segregated into three groups of 30 samples each. 0.022 slot metal MBT brackets (Gemini series-3M unitek) were bonded with self-etch primer using Transbond XT composite, CA, USA and light cure for 40 seconds) on clean buccal surface. Teeth were divided into 3 groups-Group A/Control group, Group B, Group C. A computer was used to record the force applied to debond the bonded bracket in the unit of Newton. The analysis of variance indicated that there were significant differences (F value = 6.891, p value=0.002) in bond strengths between the various groups tested. The highest value of shear bond strength occurred when chlorhexidine (Group C) was used to remove the blood contamination (mean=15.874 MPa). When bonding was done in ideal condition (Group A), shear bond strength obtained was slightly lower (mean=14.497 MPa) as compared to Group C. On the other hand, lowest shear bond strength among all three groups occurred when blood contamination (Group B) was removed with water (mean=11.059 MPa). Analysis of the study showed that shear bond strength of orthodontic brackets to enamel significantly decreased during bonding with self-etch primer in blood contamination condition. Self-etch primer displayed considerably superior performance with the use of chlorhexidine instead of water to wash the blood contamination.
More Related Videos
03:02Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
08:20Systematic Approach to Identify Novel Antimicrobial and Antibiofilm Molecules from Plants' Extracts and Fractions to Prevent Dental Caries
Published on: March 31, 2021
Related Concept Videos
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
Hand hygiene
Hand washing...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
EDTA: Auxiliary Complexing Reagents
Bonding and Strength of Aggregate