Related Experiment Video
Updated: Aug 4, 2025

Environmental Dynamic Mechanical Analysis to Predict the Softening Behavior of Neural Implants
Published on: March 1, 2019
Effects of different storage temperatures on the properties of nonlatex orthodontic modules
Shivam Sharma1, Ashish K Singh1, Puneet Batra1
1Department of Orthodontics and Dentofacial Orthopedics, Manav Rachna Dental College, Faridabad, Haryana, India.
Objective:
To evaluate and compare the effect of variation in storage temperatures and duration on a tensile load at failure of elastomeric modules.
Methods:
In total, 140 modules were used in the study, 20 of which were tested on day 0 as received from a company using a Universal testing machine for baseline estimation of tensile load at failure. The rest 120 modules were divided into 6 groups. Groups I, II, and III modules were stored at low (T1 = 1-5°C), moderate (T2 = 20-25°C) and high (T3 = 35-40°C) temperatures, respectively, for 6 months. Groups IV, V and VI modules were stored at temperatures T1, T2 and T3 for 1 year, respectively, and were tested for tensile load at failure.
Results:
The tensile load at failure for the control group was 21.588 ± 1.082 N and for 6-month interval at temperatures T1, T2 and T3 was 18.818 N ± 1.121 N, 17.841 N ± 1.334 N and 17.149 N ± 1.074 N, respectively, and for 1 year, it was 17.205 N ± 1.043 N, 16.836 N ± 0.487 N and 14.788 N ± 0.781 N, respectively. The tensile load at failure decreased significantly from 6 months to 1 year among each temperature group.
Conclusions:
Maximum force degradation was seen in modules at high temperature followed by medium temperature and low temperature at both 6 months and 1 year intervals, and tensile load at failure decreased significantly from 6 months to 1 year storage duration. These results conclude that the temperature and duration at which the samples were exposed during storage produce a significant change in the forces exerted by the modules.
More Related Videos
11:06Design and Fabrication of an Elastomeric Unit for Soft Modular Robots in Minimally Invasive Surgery
Published on: November 14, 2015
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Temperature Dependent Deformation
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Thermal Stress