In vivo microstructural investigation of the human tympanic membrane by endoscopic polarization-sensitive optical
Svea Steuer1,2, Joseph Morgenstern3,4, Lars Kirsten1
1TU Dresden, Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Dresden, Germany.
Significance:
Endoscopic optical coherence tomography (OCT) is of growing interest for in vivo diagnostics of the tympanic membrane (TM) and the middle ear but generally lacks a tissue-specific contrast.
Aim:
To assess the collagen fiber layer within the in vivo TM, an endoscopic imaging method utilizing the polarization changes induced by the birefringent connective tissue was developed.
Approach:
An endoscopic swept-source OCT setup was redesigned and extended by a polarization-diverse balanced detection unit. Polarization-sensitive OCT (PS-OCT) data were visualized by a differential Stokes-based processing and the derived local retardation. The left and right ears of a healthy volunteer were examined.
Results:
Distinct retardation signals in the annulus region of the TM and near the umbo revealed the layered structure of the TM. Due to the TM's conical shape and orientation in the ear canal, high incident angles onto the TM's surface, and low thicknesses compared to the axial resolution limit of the system, other regions of the TM were more difficult to evaluate.
Conclusions:
The use of endoscopic PS-OCT is feasible to differentiate birefringent and nonbirefringent tissue of the human TM in vivo. Further investigations on healthy as well as pathologically altered TMs are required to validate the diagnostic potential of this technique.
More Related Videos
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...