Abstract:
This paper proposes and experimentally validates a novel concentric circle (CC) model for indoor WiFi sensing. By setting the transmitter and receiver together, the perception model becomes concentric circles with equal spacing, eliminating the blind zone and unequal radial sensitivity problems of the Fresnel zone (FZ) model. Then a human respiratory monitoring system is developed based on this model, which executes the following steps: (1) Principal component analysis (PCA) is applied to the channel state information ratio (CSIR) as a preprocessing to extract the components related to human activities. (2) Human presence and respiratory signal detection are adopted to improve monitoring accuracy. (3) The Doppler respiratory frequency is extracted to calculate the respiratory rate. Experimental results show that the CC model achieves high accuracy in velocity measurement with an error of less than 0.4 cm/s. The respiration monitoring system can accurately monitor human respiration with an error of less than 0.7 bpm within 6 m.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Neural Control of Respiration
Respiratory Centers in the Brainstem
Two primary areas comprise the respiratory center: the medullary respiratory center in the medulla oblongata and the pontine respiratory group in the pons. The...
Pulse rhythm