Related Experiment Video
Updated: Aug 4, 2025

Acquisition and Semi-Automated Analysis of Respiratory Muscle Surface Electromyography
Published on: January 24, 2025
The Effects of Automatic Inspiratory Rise Time and Flow Termination on Operation of Closed-Loop Ventilation
Shih Hsing Yang1, Chin Pyng Wu2, Yuh Chin T Huang3
1Department of Respiratory Therapy, Fu Jen Catholic University, New Taipei City, Taiwan.
Background:
Adaptive ventilation mode (AVM) is a automated mode of mechanical ventilation. AVM is comprable to adaptive support ventilation (ASV). Both recommend a tidal volume (VT) and breathing frequency (f) combination based on lung mechanics, but AVM also automatically adjusts rise time and flow termination of pressure support breaths. How these added features of AVM affect VT and f recommendations compared to ASV is not clear. The present study compared these 2 modes in a test lung with obstructive and restrictive mechanics.
Methods:
The experiment was performed in a simulated lung model in which the compliance (C) and resistance (R) could be altered independently. The ventilatory parameters at different minute volumes (MinVol%) in AVM or ASV mode were recorded.
Results:
When MinVol% was set at 100%, AVM provided a similar VT and f combination compared to ASV with decreasing compliance or increasing resistance. However, when MinVol% was increased to 250% simulating hyperventilation, for the severely obstructive lung (C60, R70) model, AVM provided a significantly higher f (26 ± 0.6 breaths/min vs 7.00 ± 0 breaths/min in ASV) and lower VT (240 ± 80 mL vs 491 ± 131 mL in ASV).
Conclusions:
The addition of automatic control of rise time and flow termination functions did not affect recommended ventilator settings in AVM in the noncompliant or obstructive lung when minute ventilation (V̇E) was low. At higher V̇E, AVM compared to ASV recommended a ventilatory strategy with lower VT and higher f. These results need to be validated in patients.
More Related Videos
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...

