Related Experiment Video
Updated: Aug 4, 2025

Preparation of High-Quality Fermented Fish Product
Published on: August 23, 2019
Correlation of tangible quality parameters of vegetable-based transformer fluids
Adango Miadonye1, Mumuni Amadu1, James Stephens2
1School of Science & Technology, Cape Breton University, Sydney, NS, Canada.
Abstract:
Due to the inherent environmental footprint of petroleum derived transformer fluids, the power industry is gradually exploring the potential of vegetable oils as alternatives. The impetus comes mostly from vegetable oils renewability and their inherent biodegradability. However, the major drawback in the use of vegetable oils as dielectric fluids is their lower oxidative stability and higher kinematic viscosity compared to mineral oils. The results obtained clearly demonstrate the correlation between spectroscopic data induction time, kinematic viscosity, acid value, and peroxide value. Quantitatively, the absorption frequencies of functional groups in vegetable oil transformer fluids that can be correlated to the mentioned quality parameters show noticeable changes with aging/oxidative degradation. The study also demonstrates the utility of integrating spectroscopic data to understand trends in induction time and kinematic viscosity of oil samples heated under transformer service conditions.
Related Concept Videos
Instrument Transformers
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
The Ideal Transformer
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's...
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular...
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...