Related Experiment Video
Updated: Aug 3, 2025

A Rat Tibial Growth Plate Injury Model to Characterize Repair Mechanisms and Evaluate Growth Plate Regeneration Strategies
Published on: July 4, 2017
The Fate of the Bent Rod in Children With Osteogenesis Imperfecta
David J Fralinger1, Denver B Kraft, Kenneth J Rogers
1Department of Orthopaedics, Nemours Children's Health, Delaware Valley, Wilmington, DE.
Background:
Osteogenesis imperfecta (OI) is a genetic disorder characterized by brittle bones and long bone deformity. Realignment and intramedullary rodding with telescopic rods are indicated for progressive deformity and can help prevent fractures. Rod bending is a reported complication of telescopic rods and a common indication for revision; however, the fate of bent lower extremity telescopic rods in the setting of OI has not been reported.
Methods:
Patients with OI at a single institution who underwent lower extremity telescopic rod placement with at least 1-year follow-up were identified. Bent rods were identified, and for these bone segments, we collected the location and angle of bend, subsequent telescoping, refracture, increasing angulation of bend, and date of revision.
Results:
One hundred sixty-eight telescopic rods in 43 patients were identified. Forty-six rods (27.4%) bent during follow-up, with an average angulation of 7.3 (range: 1 to 24) degrees. In patients with severe OI, 15.7% of rods bent compared with 35.7% in nonsevere OI ( P =0.003). The proportion of bent rods was different between independent and nonindependent ambulators (34.1% and 20.5%; P =0.035). Twenty-seven bent rods (58.7%) were revised, with 12 rods (26.0%) revised early (within 90 d). The angulation of rods that were revised early was significantly higher than rods not (14.6 and 4.3 degrees, P <0.001). Of the 34 bent rods not revised early, the average time to revision or final follow-up was 29.1 months. Twenty-five rods (73.5%) continued to telescope, 14 (41.2%) increased in angulation (average 3.2 degrees), and 10 bones (29.4%) refractured. None of the refractures required immediate rod revision. Two bones had multiple refractures.
Conclusions:
Bending is a common complication of telescopic rods in the lower extremities of patients with OI. It is more common in independent ambulators and patients with nonsevere OI, possibly because of the increased demand placed on the rods. Rods with a small bend and maintained fixation can telescope and need not be an indication for immediate revision.
Level Of Evidence:
Level III-Retrospective review.
More Related Videos
04:20Author Spotlight: Enhancing Accuracy and Reproducibility in Whole Bone Bending Tests
Published on: September 1, 2023
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...
Bone Formation by Endochondral Ossification
Changes in the Appendicular Skeleton with Age
Initially, the limb buds consist of a core of mesenchyme covered by a layer of ectoderm. The ectoderm at the end of the limb bud thickens to form a narrow crest called the apical ectodermal ridge. This ridge stimulates the underlying...
Temperature Dependent Deformation
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...