A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
Is All-on-four effective in case of partial mandibular resection? A 3D finite element study
Vangi Dario1, Gulino Michelangelo-Santo1, Branchi Roberto2
1Department of Industrial Engineering, Università degli Studi di Firenze, Via di Santa Marta 3, Firenze (FI) 50139, Italy.
Introduction:
The aim of the work is to analyze stress distribution on 3D Finite Element (FE) models at bone, implant, and framework level of different designs for fixed implant-supported prostheses in completely edentulous patients, comparing results on whole and partially resected mandibles.
Materials And Methods:
3D anisotropic FE models of a whole and of a partially resected mandible were created using a TC scan of a cadaver's totally edentulous mandible. Two types of totally implant-supported rehabilitation were simulated, with four implants: parallel fixtures on whole mandible and on resected mandible, All-on-four-configured fixtures on whole mandible and on partially resected mandible. A superstructure comprising only metal components of a prosthetic framework were added, while stress distribution and its maximum values were analyzed at bone, implant, and superstructure level.
Results:
The results highlight that: (1) implant stresses are greater on the whole mandible than on the resected one; (2) framework and cancellous-bone stresses are comparable in all cases; (3) on the resected mandible, maximum stress levels at the cortical-bone/implant interface are higher than in whole-mandible rehabilitation. The opposite applies for maximum stresses on external cortical bone, measured radially with respect to the implant from the point of maximum stress at the interface.
Discussion:
On the resected mandible, All-on-four configuration proved biomechanically superior to parallel implants considering radial stresses on implants and cortical bone. Still, maximum stresses increase at the bone/implant interface. A design with four parallel implants minimizes the stress on a resected mandible while, on the whole mandible, the All-on-four rehabilitation proves superior at all levels (bone, implant, and framework).