An application of raman spectroscopy in combination with machine learning to determine gastric cancer spectroscopy
Zozan Guleken1, Paweł Jakubczyk2, Wiesław Paja3
1Department of Physiology, Faculty of Medicine, Gaziantep University of Islam Science and Technology, Gaziantep, Turkey; İstanbul Atlas University Faculty of Medicine, Istanbul, Turkey.
Background And Objective:
Globally, gastric carcinoma (Gca) ranks fifth in terms of incidence and third in terms of mortality. Higher serum tumor markers (TMs) than those from healthy individuals, led to TMs clinical application as diagnostic biomarkers for Gca. Actually, there is no accurate blood test to diagnose Gca.
Methods:
Raman spectroscopy is applied as an efficient, credible, minimally invasive technique to evaluate the serum TMs levels in blood samples. After curative gastrectomy, serum TMs levels are important in predicting the recurrence of gastric cancer, which must be detected early. The experimentally assesed TMs levels using Raman measurements and ELİSA test were used to develop a prediction model based on machine learning techniques. A total of 70 participants diagnosed with gastric cancer after surgery (n = 26) and healthy (n = 44) were comrpised in this study.
Results:
In the Raman spectra of gastric cancer patients, an additional peak at 1182 cm-1 was observed and, the Raman intensity of amide III, II, I, and CH2 proteins as well as lipids functional group was higher. Furthermore, Principal Component Analysis (PCA) showed, that it is possible to distinguish between the control and Gca groups using the Raman range between 800 and 1800 cm-1, as well as between 2700 and 3000 cm-1. The analysis of Raman spectra dynamics in gastric cancer and healthy patients showed, that the vibrations at 1302 and 1306 cm-1 were characteristic for cancer patients. In addition, the selected machine learning methods showed classification accuracy of more than 95%, while obtaining an AUROC of 0.98. Such results were obtained using Deep Neural Networks and the XGBoost algorithm.
Conclusions:
The obtained results suggest, that Raman shifts at 1302 and 1306 cm-1 could be spectroscopic markers of gastric cancer.
More Related Videos
08:08Detection and Isolation of Cancer in Prostate Biopsies Using Stimulated Raman Histology and Artificial Intelligence
Published on: June 10, 2025
07:54Surface-enhanced Resonance Raman Scattering Nanoprobe Ratiometry for Detecting Microscopic Ovarian Cancer via Folate Receptor Targeting
Published on: March 25, 2019
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...