Objective:
Fluorine-18-fluorodeoxyglucose (18F-FDG) injection activity is positively associated with radiation dose and positron emission tomography (PET) image count. Measurement error is greater with smaller counts; therefore, precise analysis is needed to avoid high doses of radiation exposure caused by high 18F-FDG injection. We aimed to identify and validate the optimal 18F-FDG injection activity and acquisition time for cardiac viability imaging with intravenous insulin preparation administration based on fixed 18F-FDG activity.
Materials And Methods:
Cardiac PET images from 30 patients with coronary artery disease (CAD) were retrospectively reconstructed into different durations. An optimal product of the maximum standardized uptake value (SUV) of the myocardium, and segmental uptake (SU), and acquisition time (MSAT) was determined through a receiver operating characteristic curve.
Results:
The optimal acquisition time (OAT) was equal to MSAT divided by mean SUV of the myocardium (MyoSUV) and was validated in another 26 patients with CAD. The optimal MSAT was 848.2s. In the validation group, the OAT was 129±76s (95% confidence interval, 99-160s), approximately one-third of the usual acquisition time. The MyoSUV and SU were equivalent between PET image duration of OAT and 600s (7.71±3.01 vs. 7.56±2.94; 67.1±15.4% vs. 67.7±15.6%).
Conclusion:
Intravenous insulin preparation administration has the potential to decrease the radiation exposure or acquisition time in cardiac viability 18F-FDG imaging to one-third, without losing the accurate measurement of MyoSUV or SU when reaching an OAT.
More Related Videos
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies VII: Vascular Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...