An inclined detector geometry for improved X-ray total scattering measurements
Nicholas Burns1, Aly Rahemtulla1,2, Scott Annett1
1Department of Physics, University of Guelph, Guelph, Ontario, Canada.
Abstract:
X-ray total scattering measurements are implemented using a digital flat-panel area detector in an inclined geometry and compared with the traditional geometry. The traditional geometry is defined here by the incident X-ray beam impinging on and normal to the center-most pixel of a detector. The inclined geometry is defined here by a detector at a pitch angle α, set to 15° in this case, bisected by the vertical scattering plane. The detector is positioned such that the incident X-ray beam strikes the pixels along the bottom edge and 90° scattered X-rays impinge on the pixels along the top edge. The geometric attributes of the inclined geometry translate into multiple benefits, such as an extension of the measurable scattering range to 90°, a 47% increase in the accessible magnitudes of the reciprocal-space vector Q and a leveling of the dynamic range in the measured total scattering pattern. As a result, a sixfold improvement in signal-to-noise ratios is observed at higher scattering angles, enabling up to a 36-fold reduction in acquisition time. Additionally, the extent of applied modification functions is reduced, decreasing the magnitude of termination ripples and improving the real-space resolution of the pair distribution function G(r). Taken all together, these factors indicate that the inclined geometry produces higher quality data than the traditional geometry, usable for simultaneous Rietveld refinement and total scattering studies.
More Related Videos
11:27Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
Published on: December 8, 2016
10:00Energy Dispersive X-ray Tomography for 3D Elemental Mapping of Individual Nanoparticles
Published on: July 5, 2016
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Scanning Electron Microscopy
Fundamental Principles
Accelerated...