Delivery of Aerosolized Bronchodilators by High-Flow Nasal Cannula During COPD Exacerbation
Nicolás Colaianni-Alfonso1, Ronan MacLoughlin2,3,4, Ariel Espada5
1Respiratory Intermediate Care Unit, Hospital General de Agudos Juan A. Fernández, Ciudad Autónoma de Buenos Aires, Argentina. nicolkf@gmail.com.
Background:
Bronchodilator delivery via a high-flow nasal cannula (HFNC) has generated interest in recent years. The efficacy of in-line vibrating mesh nebulizers with an HFNC during COPD exacerbation is limited. The aim of this study was to evaluate the clinical response of subjects with COPD exacerbation who require bronchodilator therapy (anticholinergic and β-agonist) by using a vibrating mesh nebulizer in line with an HFNC.
Methods:
This was a prospective single-center study performed in a respiratory intermediate care unit that enrolled patients with a diagnosis of COPD exacerbation who required noninvasive ventilation on admission. All the subjects underwent noninvasive ventilation breaks with an HFNC. After clinical stability, pulmonary function tests were performed to assess changes in FEV1 and clinical parameters before and after bronchodilation by using a vibrating mesh nebulizer in line with an HFNC.
Results:
Forty-six patients with COPD exacerbation were admitted. Five patients who did not use noninvasive ventilation and 10 patients who did not receive bronchodilator treatment with a vibrating mesh nebulizer were excluded. Thirty-one were selected, but 1 subject was secondarily excluded due to loss of data. Finally, 30 subjects were included. The primary outcome was spirometric changes in FEV1. The mean ± SD FEV1 before receiving bronchodilator treatment by using a vibrating mesh nebulizer in line with an HFNC was 0.74 ± 0.10 L, and, after receiving treatment, the mean ± SD FEV1 changed to 0.88 ± 0.12 L (P < .001). Similarly, the mean ± SD FVC increased from 1.75 ± 0.54 L to 2.13 ± 0.63 L (P < .001). Considerable differences were observed in breathing frequency and heart rate after receiving bronchodilator treatment. No relevant changes were observed in the Borg scale or Sp O after treatment. The mean clinical stability recorded was 4 d.
Conclusions:
In subjects with COPD exacerbation, bronchodilator treatment by using a vibrating mesh nebulizer in line with an HFNC showed a mild but significant improvement in FEV1 and FVC. In addition, a decrease in breathing frequency was observed, suggesting a reduction in dynamic hyperinflation.
Related Concept Videos
COPD: Management Using Bronchodilators and Corticosteroids
Inhaled Medications
Chronic Obstructive Pulmonary Disease-V: Management
Smoking Cessation
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Drugs Used in Lower Respiratory Disorders: Overview
Bronchodilators, the first step of respiration enhancement, come in various forms, each with its own mechanism...