Related Experiment Video
Updated: Aug 3, 2025

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
CT doses based on clinical indications. New national DRL's in Iceland
Jónína Guðjónsdóttir1, Sigurbjörg Sigurðard Michelsen2, Guðlaug Björnsdóttir2
1Icelandic Radiation Safety Authority. Rauðarárstígur 10, 105 Reykjavík, Iceland; University of Iceland, Faculty of Medicine. Vatnsmýrarvegur 16, 101 Reykjavík, Iceland.
Abstract:
A diagnostic reference level (DRL) is an investigation level to use in the optimization of a medical exposure using ionizing radiation. The aim of this project was to gather dose data from computed tomography (CT) studies in Iceland with the purpose of updating existing national DRL and proposing DRLs based on clinical indications. Dose data (total dose length product (DLP) and CT dose index) were retrospectively collected from all CT scanners in Iceland for 50 patients for all common CT studies. After cleaning the data, the data set contained total DLP for 8129 patients. Considering dose-relevant parameters such as the number of phases and scan length, each CT study was assigned to one of 42 study types and (at least) one clinical indication. Data were received from seven or more scanners for 13 clinical indications and from all scanners providing coronary angiography. There was considerable variation in the median total DLP from different scanners, e.g., from 13 to 139 mGycm for Sinusitis, and, the range of individual total DLPs varied between scanners. This underscores the importance of monitoring patients' exposure. The study shows that there is room for optimization. New Icelandic NDRLs were proposed for the total DLP of CT examinations based on ten different indications, including: Brain ischemia (1060 mGycm), Interstitial lung disease (310 mGycm) and Appendicitis (690 mGycm). The proposed NDRLs were the first clinical indication based NDRLs in Iceland. The Icelandic Radiation Safety Authority has decided to update the NDRLs based on the results of this study.
More Related Videos
Related Concept Videos
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...
Radiological Investigation I: X-ray and CT
Nursing Interventions II: Selecting and Classifying the Nursing Interventions
Clinical Trials: Overview
Drug Dosage Regimen: Overview
Typically, the starting dose and dosing interval are guided by the manufacturer's recommendations based on clinical trials conducted during and after drug...