Related Experiment Video
Updated: Aug 2, 2025

Real-Time Proxy-Control of Re-Parameterized Peripheral Signals using a Close-Loop Interface
Published on: May 8, 2021
Practical Implementation of the Indirect Control to the Direct 3 × 5 Matrix Converter Using DSP and Low-Cost FPGA
Michal Praženica1, Patrik Resutík1, Slavomír Kaščák1
1Department of Mechatronics and Electronics, Faculty of Electrical Engineering and Information Technology, University of Zilina, 010 01 Zilina, Slovakia.
Abstract:
The popularity of multiphase drives is increasing due to the growing interest in drives with more than three phases. One promising topology is the multiphase matrix converters, which enable the implementation of a single-stage AC/AC power conversion system with bidirectional power flow capability. In this paper, we present the implementation of indirect control for a practical sample of the direct matrix converter. To reduce the overall cost of the control solution for these types of converters, we utilized low-cost FPGA and DSP. The usage of only DSP itself was not possible due to low number of available PWM output needed for 3 × 5 MxC driving. Another reason is commutation, which must be precise and fast to avoid any hazardous states in the converter. Due to these problems, the authors decided to implement an algorithm of a combination of DSP and FPGA, where FPGA is used for time critical operations. The indirect algorithm treats the converter as two separate parts, the rectifier and the inverter, with the DC-LINK being fictitious. The matrix converter is composed of compact modules, and the entire system is verified. The practical verification demonstrates that matrix converters can produce a wide range of output frequencies and achieve input power factor control. Finally, we compare and review the practical model with the simulation model, examining efficiency and other parameters.
More Related Videos
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
11:13Design and Implementation of an Automated Illuminating, Culturing, and Sampling System for Microbial Optogenetic Applications
Published on: February 19, 2017
Related Concept Videos
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
PI Controller: Design
Control Systems: Applications
In modern vehicles, control systems manage various functions to enhance performance and safety. The steering wheel and accelerator are primary inputs in a car's control system. The...
Block Diagram Reduction
The first step in this process is the identification and relocation of a branch point. A branch point, where a...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Operational Amplifiers