Gumbel distribution-based technique enables quantitative comparison between streak metal artifacts of multidetector
Yoshikazu Nomura1, Hiroshi Watanabe2, Hiroshi Tomisato3
1Department of Dental Radiology and Radiation Oncology, Graduate School, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan. ynmr.orad@tmd.ac.jp.
Abstract:
Cone-beam computed tomography (CBCT), derived from multidetector row CT (MDCT), has a high spatial resolution and has recently been applied to various organs. One of the severe limitations common to CBCT and MDCT is metal artifacts. In particular, streak metal artifacts (SMAs) between multiple metal materials often hinder diagnosis. However, no studies have quantitatively compared the strength of SMAs in MDCT and CBCT. Nomura et al. reported an evaluation method specialized in SMAs of CBCT using the Gumbel distribution (GD), which can also be applied to SMAs of MDCT (Oral Surg Oral Med Oral Pathol Oral Radiol 131: 494-502, 2021, https://doi.org/10.1016/J.OOOO.2020.08.031 ). This study aimed to quantitatively compare SMAs occurring between titanium materials on MDCT and CBCT images using the GD-based method. The SMAs were investigated as follows: A hydroxyapatite block was sandwiched between two titanium rods to generate an SMA. They were placed in an acrylic phantom, simulating a human head, and scanned using an MDCT scanner and two CBCT scanners. The obtained images were analyzed using Gumbel plots and location parameters, and the SMA strength was calculated. The results showed that the SMAs on the MDCT images were significantly weaker than those on the CBCT images. In the CBCT scans, a smaller volume CT dose index value caused stronger SMAs. These results indicate that MDCT is more advantageous than CBCT in terms of SMA reduction when bone morphology between titanium materials must be evaluated. The characteristic should be considered in clinical cases.
More Related Videos
09:00Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography
Published on: September 29, 2019
07:013D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Imaging Studies for Cardiovascular System V: CT