Thinning of the Lamina Cribrosa and Deep Layer Microvascular Dropout in Patients With Open Angle Glaucoma and High
Yanhui Chen1,2, Baoyue Mi1, Haoru Li1
1Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China.
PréCis:
Lamina cribrosa (LC) thinning (thickness of ≤128.00 µm) helps to distinguish open angle glaucoma from high myopia, which was associated with the presence of microvasculature dropout and elevated intraocular pressure.
Purpose:
The purpose of this study was to analyze the factors associated with LC thickness in highly myopic eyes with and without open angle glaucoma.
Methods:
In total, 240 highly myopic eyes with γ-zones (194 eyes without and 46 eyes with open angle glaucoma) were examined, and the LC center, externally oblique border, an abrupt change of scleral curvature (scleral step), deep layer microvasculature dropout and global retinal nerve fiber layer thickness were investigated on optical coherence tomography and optical coherence tomography angiography.
Results:
LC were thinner in highly myopic open angle glaucoma compared with high myopia alone (107.76±9.86 vs. 137.07±18.51 µm, P <0.001), which was associated with deep layer microvasculature dropout and elevated intraocular pressure. The areas under the receiver operating characteristic curve for detecting open angle glaucoma from the LC thickness was 0.964, which was statistically higher ( P <0.05) than from the global retinal nerve fiber layer thickness (0.921) and vertical cup-to-disc ratio (0.902). A LC thickness cutoff value of 128 µm provided 100% sensitivity for detecting open angle glaucoma with 84% specificity.
Conclusions:
Highly myopic eyes with open angle glaucoma appear to have a thinner LC, which was associated with elevated intraocular pressure and deep layer microvasculature dropout. LC thinning (≤128.00 µm) helps distinguish open angle glaucoma from high myopia with an abnormal retinal nerve fiber layer thickness distribution and unclear shallow disc cupping.
More Related Videos
10:10Full-Circle Cauterization of Limbal Vascular Plexus for Surgically Induced Glaucoma in Rodents
Published on: February 15, 2022
08:55Translaminar Autonomous System Model for the Modulation of Intraocular and Intracranial Pressure in Human Donor Posterior Segments
Published on: April 24, 2020
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Photoreceptors and Visual Pathways
Anatomy of the Eyeball