Related Experiment Video
Updated: Aug 2, 2025

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Measuring downstream supply chain losses due to power disturbances
1National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD.
None:
Power outages in the U.S. affect many firms' economic activity and are likely to result in downstream supply chain disruptions. This paper examines the impact of power disturbances in the supply chain for four industries: manufacturing, durable goods manufacturing, nondurable goods manufacturing, and total private industry. This indirect impact includes the losses at downstream firms that might not receive supplies on time due to disturbances at their suppliers' facilities. This is measured using observations of value added before and after power disturbances rather than the more common method of modeling an economy. This paper tests four hypotheses related to the effect of power disturbances with all four of them being supported by the model results. Further, using simulation we estimate the indirect costs of power disturbances. The results suggest that power disturbances have a statistically significant effect on gross domestic product (i.e., value added), particularly in manufacturing where power disturbances in the supply chain had a statistically significant effect. While this industry represents 12.8 % of private industry value added, it experiences 36.8 % of the supply chain losses due to power disturbances, as suggested by the results of the simulation. Power disturbances in the supply chain affected all four industries with nondurable goods being affected the most. This creates a significant disconnect between the stakeholder that invests in reliability in the power grid and the stakeholders that experience the bulk of losses.
Related Concept Videos
Distribution Reliability and Automation
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
Lossy Lines and Overvoltages
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Power System Three-Phase Short Circuits