The Effect of Ambient Air Pollution on Office, Home, and 24-Hour Ambulatory Blood Pressure Measurements
Şükrü Ulusoy1, Gülsüm Özkan2, Gamze Varol3
1Department of Nephrology, School of Medicine, Karadeniz Technical University, Trabzon, Turkey.
Background:
Air pollution has recently been linked to a number of cardiovascular diseases, particularly hypertension (HT). In our study, we aimed to evaluate the association between air pollution and blood pressure (BP) and compare the relationship of BP measurement results obtained using different methods (office, home, and 24-hour ambulatory BP monitoring [ABPM]).
Methods:
This retrospective nested panel study performed with prospective Cappadocia cohort data investigated the relationships between particulate matter (PM) 10 and sulfur dioxide (SO2) and concurrent home, office, and 24-hour ABPM data at each control performed over a 2-year period.
Results:
A total of 327 patients in the Cappadocia cohort were included in this study. On the day of office blood pressure measurement, there was an increase of 1.36 mm Hg in systolic BP and 1.18 mm Hg in diastolic BP for every 10 µm/m3 rise in SO2 values. A mean 3-day 10 µm/m3 increase in SO2 was linked to an increase of 1.60 mm Hg in systolic BP and 1.33 mm Hg in diastolic BP. A 10 µm/m3 rise in mean SO2 on the day of 24-hour ABPM measurement was found to be associated with an increase of 1.3 mm Hg in systolic BP and 0.8 mm Hg in diastolic BP. SO2 and PM 10 had no effect on home measurements.
Conclusion:
In conclusion, increased SO2 levels, during winter months in particular, can be associated with an elevation in office BP values. Our study findings show that air pollution in the setting in which BP is measured may be associated with the results.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Hypertension III: Clinical Manifestations and Diagnostic Studies
Factors affecting Blood pressure
Physiological Factors:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...