Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
The diagnostic performance of AccuFFRangio for evaluating coronary artery stenosis under different computational
Wei Wang1, Yumeng Hu2, Peng Xiang3
1Department of Cardiology, The First Affiliated Hospital of Anhui Medical University, Hefei, China.
Background:
A computational method (AccuFFrangio) based on invasive coronary angiography (ICA) and computational fluid dynamics (CFD) to calculate fractional flow reserve (FFR) without a pressure wire has been devised to clarify the physiological significance of coronary stenosis. This study aimed to evaluate the diagnostic performance of AccuFFRangio computation under different boundary conditions and vessel reconstruction approaches.
Methods:
Consecutive patients with stable angina pectoris who underwent ICA and FFR assessment from 2 centers were analyzed retrospectively. Using wire-based FFR as the reference standard, the diagnostic performances of AccuFFRangio and its variations were evaluated and compared. The calculation of AccuFFRangio involves several key boundary conditions, including patient-specific aortic pressure, contrast flow velocity derived from the thrombolysis in myocardial infarction (TIMI) frame count method, and vessel reconstruction based on 2 angiographic views. We considered the following 3 variations: (I) a fixed aortic pressure [fixed pressure AccuFFRangio (pAccuFFRangio)], (II) an empirical hyperemic velocity [fixed velocity AccuFFRangio (vAccuFFRangio)], and (III) vessel reconstruction using a single angiographic view [single view AccuFFRangio (sAccuFFRangio)].
Results:
A total of 230 patients with 230 vessels were included in the final analysis. The accuracy for standard AccuFFRangio, pAccuFFRangio, vAccuFFRangio, and sAccuFFRangio was 93.91%, 86.52%, 81.74%, and 83.48%, respectively; the sensitivity was 90.74%, 51.85%, 83.33%, and 46.30%, respectively; the specificity was 94.89%, 97.16%, 81.25%, and 94.89%, respectively; and the area under the receiver operating characteristic curve was 0.971, 0.928, 0.892, and 0.870, respectively.
Conclusions:
The comparison suggested that the overall performance of the standard AccuFFRangio was superior to other variations and had the highest accuracy among all the cases.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
05:58Testing Acetylcholine Followed by Adenosine for Invasive Diagnosis of Coronary Vasomotor Disorders
Published on: February 3, 2021
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT