Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Molecular Spectroscopy: Absorption and Emission01:14

Molecular Spectroscopy: Absorption and Emission

2.4K
Molecules possess discrete energy levels called quantum states. Unlike atoms, which have simpler energy levels, molecules possess additional rotational and vibrational energy levels.  Each energy level is separated by an energy gap, with the gaps between adjacent electronic, vibrational, and rotational levels varying significantly. The three types of energy levels in a diatomic molecule are shown in Figure 1.
2.4K
UV–Vis Spectroscopy: Molecular Electronic Transitions01:16

UV–Vis Spectroscopy: Molecular Electronic Transitions

1.6K
In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this...
1.6K
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

813
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
813
Atomic Spectroscopy: Absorption, Emission, and Fluorescence01:23

Atomic Spectroscopy: Absorption, Emission, and Fluorescence

1.1K
Atomic spectroscopy is a vital tool in elemental analysis, both qualitatively and quantitatively. It can be broadly divided into optical spectroscopy, mass spectroscopy, and X-ray spectroscopy methods. The optical spectroscopic methods are atomic absorption spectroscopy (AAS), atomic emission spectroscopy (AES), and atomic fluorescence spectroscopy (AFS). The first step in all three methods is atomization, where the solid, liquid, or solution-phase samples are converted into gas-phase atoms and...
1.1K
Atomic Absorption Spectroscopy: Overview01:27

Atomic Absorption Spectroscopy: Overview

2.3K
Atomic absorption spectroscopy (AAS) is a technique used to analyze elements by measuring electromagnetic radiation (EMR) absorbed by atoms, which causes them to transition to a higher-energy orbit. The most crucial step in AAS is atomization, where the analyte is converted into gas-phase atoms, typically through a flame or furnace. Some of these atoms become thermally excited in the flame, while most remain in the ground state.
When irradiated by EMR of a particular wavelength, these...
2.3K
Atomic Absorption Spectroscopy: Radiation and Light Sources01:13

Atomic Absorption Spectroscopy: Radiation and Light Sources

455
Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
455

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Advantage of Coherent States in Ring Resonators over Any Quantum Probe Single-Pass Absorption Estimation Strategy.

Physical review letters·2022
Same author

Generating path entangled states in waveguide systems with second-order nonlinearity.

Optics express·2020
Same journal

Erratum: Bacterial Turbulence at Compressible Fluid Interfaces [Phys. Rev. Lett. 136, 138301 (2026)].

Physical review letters·2026
Same journal

Unveiling Light-Quark Yukawa Flavor Structure via Dihadron Fragmentation at Lepton Colliders.

Physical review letters·2026
Same journal

Adaptable Route to Fast Coherent State Transport via Bang-Bang-Bang Protocols.

Physical review letters·2026
Same journal

Topological Transition and Emergence of Elasticity of Dislocation in Skyrmion Lattice: Beyond Kittel's Magnetic-Polar Analogy.

Physical review letters·2026
Same journal

Pound-Drever-Hall Method for Superconducting-Qubit Readout.

Physical review letters·2026
Same journal

Coupling a ^{73}Ge Nuclear Spin to an Electrostatically Defined Quantum Dot in Silicon.

Physical review letters·2026
See all related articles

Related Experiment Video

Updated: Aug 2, 2025

Generation and Coherent Control of Pulsed Quantum Frequency Combs
06:42

Generation and Coherent Control of Pulsed Quantum Frequency Combs

Published on: June 8, 2018

9.0K

Quantum-Enhanced Absorption Spectroscopy with Bright Squeezed Frequency Combs.

Alexandre Belsley1

  • 1Quantum Engineering Technology Labs, H. H. Wills Physics Laboratory and Department of Electrical and Electronic Engineering, University of Bristol, Bristol BS8 1FD, United Kingdom and Quantum Engineering Centre for Doctoral Training, H. H. Wills Physics Laboratory and Department of Electrical and Electronic Engineering, University of Bristol, Bristol BS8 1FD, United Kingdom.

Physical Review Letters
|April 17, 2023
PubMed
Summary
This summary is machine-generated.

This study introduces a novel gas sensing technique combining frequency modulation spectroscopy with quantum squeezing for enhanced detection. The method significantly improves signal-to-noise ratio, enabling highly precise gas analysis beyond standard limits.

More Related Videos

High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy
10:40

High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy

Published on: June 28, 2016

7.6K
Quantum State Engineering of Light with Continuous-wave Optical Parametric Oscillators
09:23

Quantum State Engineering of Light with Continuous-wave Optical Parametric Oscillators

Published on: May 30, 2014

14.6K

Related Experiment Videos

Last Updated: Aug 2, 2025

Generation and Coherent Control of Pulsed Quantum Frequency Combs
06:42

Generation and Coherent Control of Pulsed Quantum Frequency Combs

Published on: June 8, 2018

9.0K
High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy
10:40

High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy

Published on: June 28, 2016

7.6K
Quantum State Engineering of Light with Continuous-wave Optical Parametric Oscillators
09:23

Quantum State Engineering of Light with Continuous-wave Optical Parametric Oscillators

Published on: May 30, 2014

14.6K

Area of Science:

  • Quantum optics and spectroscopy
  • Gas sensing technology

Background:

  • Absorption spectroscopy is crucial for detecting low concentrations of gas species.
  • Existing methods face limitations in sensitivity and noise reduction.

Purpose of the Study:

  • To develop an advanced gas sensing strategy by integrating frequency modulation spectroscopy with quantum-enhanced detection.
  • To achieve a significant improvement in signal-to-noise ratio (SNR) for high-precision gas analysis.

Main Methods:

  • Utilized frequency modulation spectroscopy (FMS) combined with quantum state squeezing of the probe light.
  • Employed a homodyne detection scheme for simultaneous multi-frequency absorption measurement.
  • Analyzed the robustness of the method against dispersion effects.

Main Results:

  • Predicted an exponential enhancement of the SNR with increasing squeezing factor.
  • Demonstrated the potential for achieving an order of magnitude improvement beyond the standard quantum limit.
  • Showcased the effectiveness of the homodyne detection for handling dispersion.

Conclusions:

  • The proposed quantum-enhanced spectroscopy technique offers superior precision for gas sensing applications.
  • State-of-the-art squeezing levels can facilitate unprecedented improvements in sensitivity.
  • This approach paves the way for next-generation, high-performance gas detection systems.