Related Experiment Video
Updated: Aug 2, 2025

Use of a Wireless Video-EEG System to Monitor Epileptiform Discharges Following Lateral Fluid-Percussion Induced Traumatic Brain Injury
Published on: June 21, 2019
Personalized seizure detection using logistic regression machine learning based on wearable ECG-monitoring device
Jesper Jeppesen1, Jakob Christensen2, Peter Johansen3
1Department of Clinical Neurophysiology, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
Purpose:
Wearable automated detection devices of focal epileptic seizures are needed to alert patients and caregivers and to optimize the medical treatment. Heart rate variability (HRV)-based seizure detection devices have presented good detection sensitivity. However, false alarm rates (FAR) are too high.
Methods:
In this phase-2 study we pursued to decrease the FAR, by using patient-adaptive logistic regression machine learning (LRML) to improve the performance of a previously published HRV-based seizure detection algorithm. ECG-data were prospectively collected using a dedicated wearable electrocardiogram-device during long-term video-EEG monitoring. Sixty-two patients had 174 seizures during 4,614 h recording. The dataset was divided into training-, cross-validation-, and test-sets (chronological) in order to avoid overfitting. Patients with >50 beats/min change in heart rate during first recorded seizure were selected as responders. We compared 18 LRML-settings to find the optimal algorithm.
Results:
The patient-adaptive LRML-classifier in combination with using only responders to train the initial decision boundary was superior to both the generic approach and including non-responders to train the LRML-classifier. Using the optimal setting of the LRML in responders in the test dataset yielded a sensitivity of 78.2% and FAR of 0.62/24 h. The FAR was reduced by 31% compared to the previous method, upholding similar sensitivity.
Conclusion:
The novel, patient-adaptive LRML seizure detection algorithm outperformed both the generic approach and the previously published patient-tailored method. The proposed method can be implemented in a wearable online HRV-based seizure detection system alerting patients and caregivers of seizures and improve seizure-count which may help optimizing the patient treatment.
More Related Videos
11:54Simultaneous Video-EEG-ECG Monitoring to Identify Neurocardiac Dysfunction in Mouse Models of Epilepsy
Published on: January 29, 2018
06:28Author Spotlight: Unraveling Seizure Dynamics and Novel Therapeutics for Status Epilepticus Using CMOS High-Density Microelectrode Array Systems
Published on: September 27, 2024
Related Concept Videos
Seizures: Classification
Seizures are typically classified into two main categories: focal and generalized seizures.
Focal Seizures
Focal seizures originate from specific regions of the brain. These seizures are further sub-classified into two types:
Epilepsy and Seizures: Overview
Various factors can trigger epilepsy, including genetic factors, brain damage, metabolic causes, and unknown etiology. Diagnosis of epilepsy involves electroencephalography (EEG), which...