Related Experiment Video
Updated: Aug 2, 2025

The Utilization of Oropharyngeal Intratracheal PAMP Administration and Bronchoalveolar Lavage to Evaluate the Host Immune Response in Mice
Published on: April 2, 2014
An S-like curve relationship between systemic inflammation response index (SIRI) and respiratory failure in GBS
Qiuyan Shen1, Xin Mu2, Yi Bao1
1Department of Neurology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan, 610041, People's Republic of China.
Background:
Our study examined the association between the initial systemic inflammation response index (SIRI) and respiratory failure in patients with Guillain-Barré syndrome (GBS).
Methods:
The weighted linear regression model, weighted chi-square test, logistic regression models, smooth curve fittings, and the two-piece linear regression model were utilized for data analysis.
Results:
Among the 443 GBS patients, 75 (6.9%) had experienced respiratory failure. According to logistic regression models, there existed no consistent linear relationship between respiratory failure and SIRI in model 1 (OR = 1.2, p < 0.001), model 2 (OR = 1.2, p < 0.001), and model 3 (OR = 1.3, p = 0.017). However, smooth curve fittings found an S-like curve relationship between SIRI and respiratory failure. Furthermore, when SIRI was < 6.4, there existed a positive correlation between SIRI and respiratory failure in model 1 (OR = 1.5, 95% CI = (1.3, 1.8), p < 0.0001), higher correlation in model 2 (OR = 1.6, 95% CI = (1.3, 1.8), p < 0.0001), and highest correlation in model 3 (OR = 1.6, 95% CI = (1.3, 2.5), p < 0.0001).
Conclusions:
SIRI can be used as a predictor of respiratory failure in GBS, and an S-like relationship exists between SIRI and respiratory failure at an infliction point of 6.4. When the SIRI was less than 6.4 and increased, SIRI was associated with a higher occurrence of respiratory failure. The risk of respiratory failure was no longer increased when the SIRI was over 6.4.
Related Concept Videos
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-III
Acute Respiratory Failure-IV
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Inflammatory Response I: Vascular and Cellular