Deep Learning Approach for Negation and Speculation Detection for Automated Important Finding Flagging and Extraction
Kung-Hsun Weng1, Chung-Feng Liu2, Chia-Jung Chen3
1Department of Medical Imaging, Chi Mei Medical Center, Chiali, Tainan, Taiwan.
Background:
Negation and speculation unrelated to abnormal findings can lead to false-positive alarms for automatic radiology report highlighting or flagging by laboratory information systems.
Objective:
This internal validation study evaluated the performance of natural language processing methods (NegEx, NegBio, NegBERT, and transformers).
Methods:
We annotated all negative and speculative statements unrelated to abnormal findings in reports. In experiment 1, we fine-tuned several transformer models (ALBERT [A Lite Bidirectional Encoder Representations from Transformers], BERT [Bidirectional Encoder Representations from Transformers], DeBERTa [Decoding-Enhanced BERT With Disentangled Attention], DistilBERT [Distilled version of BERT], ELECTRA [Efficiently Learning an Encoder That Classifies Token Replacements Accurately], ERNIE [Enhanced Representation through Knowledge Integration], RoBERTa [Robustly Optimized BERT Pretraining Approach], SpanBERT, and XLNet) and compared their performance using precision, recall, accuracy, and F1-scores. In experiment 2, we compared the best model from experiment 1 with 3 established negation and speculation-detection algorithms (NegEx, NegBio, and NegBERT).
Results:
Our study collected 6000 radiology reports from 3 branches of the Chi Mei Hospital, covering multiple imaging modalities and body parts. A total of 15.01% (105,755/704,512) of words and 39.45% (4529/11,480) of important diagnostic keywords occurred in negative or speculative statements unrelated to abnormal findings. In experiment 1, all models achieved an accuracy of >0.98 and F1-score of >0.90 on the test data set. ALBERT exhibited the best performance (accuracy=0.991; F1-score=0.958). In experiment 2, ALBERT outperformed the optimized NegEx, NegBio, and NegBERT methods in terms of overall performance (accuracy=0.996; F1-score=0.991), in the prediction of whether diagnostic keywords occur in speculative statements unrelated to abnormal findings, and in the improvement of the performance of keyword extraction (accuracy=0.996; F1-score=0.997).
Conclusions:
The ALBERT deep learning method showed the best performance. Our results represent a significant advancement in the clinical applications of computer-aided notification systems.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Magnetic Resonance Imaging
X-ray Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...