Abstract:
Metal oxide-based conductometric gas sensors (CGS) have showcased a vast application potential in the fields of environmental protection and medical diagnosis due to their unique advantages of high cost-effectiveness, expedient miniaturization, and noninvasive and convenient operation. Of multiple parameters to assess the sensor performance, the reaction speeds, including response and recovery times during the gas-solid interactions, are directly correlated to a timely recognition of the target molecule prior to scheduling the relevant processing solutions and an instant restoration aimed for subsequent repeated exposure tests. In this review, we first take metal oxide semiconductors (MOSs) as the case study and conclude the impact of the semiconducting type as well as the grain size and morphology of MOSs on the reaction speeds of related gas sensors. Second, various improvement strategies, primarily including external stimulus (heat and photons), morphological and structural regulation, element doping, and composite engineering, are successively introduced in detail. Finally, challenges and perspectives are proposed so as to provide the design references for future high-performance CGS featuring swift detection and regeneration.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-II