Related Experiment Video
Updated: Jul 31, 2025

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Influence of Occlusal Stress on Implant Abutment Junction and Implant Bone Interface: A Finite Element Analysis Study
Arun Kharavela Mohanty1, Thomas Varghese2, Purnendu Bhushan1
1Department of Prosthodontics, Kalinga Institute of Dental Sciences, Kalinga Institute of Industrial Technology (KIIT) Deemed to be University, Bhubaneswar, Odisha, India.
Aim:
The aim of the present study was to assess the occlusal stress on the implant-abutment junction and implant-bone interface of a long-span implant-supported prosthesis made of two different prosthetic materials.
Materials And Methods:
A computerized tomography of the mandible was used to get the finite element model of the bone. The comparative groups were made as follows: S1 and S2 - 3.7 × 11 mm (44 region) and 4.5 × 11 mm (47 region), S1A and S2A - screw-retained porcelain-fused-to-metal prosthesis, S1B and S2B - cement-retained porcelain-fused-to-metal prosthesis, S1C and S2C - screw-retained zirconia prosthesis, and S1D - cement-retained zirconia prosthesis. Maximum stress generated on the implant-abutment interface of all the prostheses under vertical and oblique load was assessed.
Results:
For all the comparative groups, maximum level of stress was generated at the cervical level of the implant-bone interface in comparison to the apical and middle-third level under both vertical and oblique load. No statistically significant difference between zirconia and porcelain-fused-to-metal prosthesis was seen at the implant-abutment interface and the cervical third of the implant-bone interface. A significant difference was found between all screw-retained and cement-retained groups.
Conclusion:
The present study concluded that the short implants in combination with standard-length implants using either porcelain-fused-to-metal or zirconia as prosthetic material in the form of long-span implant-supported prosthesis can be a viable treatment option in the posterior mandible.
Clinical Significance:
The accuracy of the diagnosis, examination, and knowledge of the site where the implant must be inserted, and the choice of superstructure is important for the stability and lifespan of the implant prosthesis.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
07:16Author Spotlight: Development of a Novel Finite Element Analysis Model for Improved Orthognathic Surgical Techniques
Published on: October 20, 2023