Related Experiment Video
Updated: Jul 31, 2025

Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Decreased breathing variability is associated with poorer outcome in mechanically ventilated patients
Camille Rolland-Debord1,2, Tymothee Poitou1,2, Come Bureau1,2
1AP-HP, Groupe Hospitalier Universitaire APHP-Sorbonne Université, site Pitié-Salpêtrière, Service de Médecine Intensive et Réanimation (Département R3S), Paris, France.
Rationale:
Breathing is a cyclic activity that is variable by nature. Breathing variability is modified in mechanically ventilated patients. We aimed to evaluate whether decreased variability on the day of transition from assist-control ventilation to a partial mode of assistance was associated with a poorer outcome.
Methods:
This was an ancillary study of a multicentre, randomised, controlled trial comparing neurally adjusted ventilatory assist to pressure support ventilation. Flow and the electrical activity of the diaphragm (EAdi) were recorded within 48 h of switching from controlled ventilation to a partial mode of ventilatory assistance. Variability of flow and EAdi-related variables were quantified by the coefficient of variation, the amplitude ratio of the spectrum's first harmonic to its zero-frequency component (H1/DC) and two surrogates of complexity.
Main Results:
98 patients ventilated for a median duration of 5 days were included. H1/DC of inspiratory flow and EAdi were lower in survivors than in nonsurvivors, suggesting a higher breathing variability in this population (for flow, 37% versus 45%, p=0.041; for EAdi, 42% versus 52%, p=0.002). By multivariate analysis, H1/DC of inspiratory EAdi was independently associated with day-28 mortality (OR 1.10, p=0.002). H1/DC of inspiratory EAdi was lower in patients with a duration of mechanical ventilation <8 days (41% versus 45%, p=0.022). Noise limit and the largest Lyapunov exponent suggested a lower complexity in patients with a duration of mechanical ventilation <8 days.
Conclusion:
Higher breathing variability and lower complexity are associated with higher survival and lower duration of mechanical ventilation.
More Related Videos
05:51Author Spotlight: Unraveling the Impact of Mechanical Ventilation on Diaphragm Function and Patient Outcomes
Published on: November 3, 2023
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Related Concept Videos
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Acute Respiratory Failure-IV
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: