Mechanical Compatibility between Mg3(Sb,Bi)2 and MgAgSb in Thermoelectric Modules
Yifan Sun1, Jiahui Fu2, Yuji Ohishi2
1Institute for Integrated Radiation and Nuclear Science, Kyoto University, 2, Asashiro-Nishi, Kumatori, Sennan-gun 590-0494 Osaka, Japan.
ACS Applied Materials & Interfaces
|May 5, 2023
Summary
Researchers improved thermoelectric module durability by alloying Mg3Sb2 with Mg3Bi2. This reduces thermal expansion mismatch with MgAgSb, enhancing mechanical robustness and performance in low-temperature applications.
Area of Science:
- Materials Science
- Thermoelectric Materials
- Solid State Chemistry
Background:
- Thermoelectric (TE) modules require mechanically robust n- and p-type legs to withstand operational temperature gradients and thermal cycling.
- Mismatched coefficients of thermal expansion (CTEs) between n-type Mg3Sb2 and p-type MgAgSb legs lead to stress and TE performance degradation.
- The oxidation resistance of these promising low-temperature TE materials at elevated temperatures is not well understood.
Purpose of the Study:
- To address the CTE mismatch between n-type Mg3Sb2 and p-type MgAgSb for improved thermoelectric module reliability.
- To investigate the thermal stability and oxidation resistance of modified Mg3Sb2 and MgAgSb in relevant operating conditions.
Main Methods:
- Alloying Mg3Sb2 with Mg3Bi2 to modify its coefficient of linear thermal expansion (CTE).
- Characterization of the CTE of the resulting Mg3Sb1.5Bi0.5 alloy.
- Thermogravimetric analysis (TGA) to assess the oxidation resistance and thermal stability of Mg3Sb1.5Bi0.5 and MgAgSb in air and argon atmospheres.
Main Results:
- Alloying Mg3Sb2 with Mg3Bi2 successfully reduced the CTE from 22.6 × 10^-6 K^-1 to 21.2 × 10^-6 K^-1 for Mg3Sb1.5Bi0.5.
- The CTE of Mg3Sb1.5Bi0.5 (21.2 × 10^-6 K^-1) closely matches that of MgAgSb (21 × 10^-6 K^-1), minimizing thermal expansion mismatch.
- Both Mg3Sb1.5Bi0.5 and MgAgSb demonstrated stability in air and argon below approximately 570 K.
Conclusions:
- The Mg3Sb1.5Bi0.5 alloy exhibits a CTE compatible with MgAgSb, effectively resolving the mismatch issue.
- The demonstrated thermal stability and oxidation resistance suggest suitability for low-temperature thermoelectric applications.
- Mg3Sb1.5Bi0.5 and MgAgSb are proposed as a robust and compatible pair of thermoelectric legs for enhanced low-temperature TE module performance and longevity.