Related Experiment Video
Updated: Jul 31, 2025

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Quantification of extracellular volume with cardiac computed tomography in patients with dilated cardiomyopathy
Andrea Baggiano1, Edoardo Conte2, Luigi Spiritigliozzi3
1Centro Cardiologico Monzino IRCCS, Milan, Italy; Cardiovascular Section, Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy.
Background:
Cardiac computed tomography (CCT) was recently validated to measure extracellular volume (ECV) in the setting of cardiac amyloidosis, showing good agreement with cardiovascular magnetic resonance (CMR). However, no evidence is available with a whole-heart single source, single energy CT scanner in the clinical context of newly diagnosed left ventricular dysfunction. Therefore, the aim of this study was to test the diagnostic accuracy of ECVCCT in patients with a recent diagnosis of dilated cardiomyopathy, having ECVCMR as the reference technique.
Methods:
39 consecutive patients with newly diagnosed dilated cardiomyopathy (LVEF <50%) scheduled for clinically indicated CMR were prospectively enrolled. Myocardial segment evaluability assessment with each technique, agreement between ECVCMR and ECVCCT, regression analysis, Bland-Altman analysis and interclass correlation coefficient (ICC) were performed.
Results:
Mean age of enrolled patients was 62 ± 11 years, and mean LVEF at CMR was 35.4 ± 10.7%. Overall radiation exposure for ECV estimation was 2.1 ± 1.1 mSv. Out of 624 myocardial segments available for analysis, 624 (100%) segments were assessable by CCT while 608 (97.4%) were evaluable at CMR. ECVCCT demonstrated slightly lower values compared to ECVCMR (all segments, 31.8 ± 6.5% vs 33.9 ± 8.0%, p < 0.001). At regression analysis, strong correlations were described (all segments, r = 0.819, 95% CI: 0.791 to 0.844). On Bland-Altman analysis, bias between ECVCMR and ECVCCT for global analysis was 2.1 (95% CI: -6.8 to 11.1). ICC analysis showed both high intra-observer and inter-observer agreement for ECVCCT calculation (0.986, 95%CI: 0.983 to 0.988 and 0.966, 95%CI: 0.960 to 0.971, respectively).
Conclusions:
ECV estimation with a whole-heart single source, single energy CT scanner is feasible and accurate. Integration of ECV measurement in a comprehensive CCT evaluation of patients with newly diagnosed dilated cardiomyopathy can be performed with a small increase in overall radiation exposure.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Cardiomyopathy II: Dilated Cardiomyopathy
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT