Radiation dose during interventional cardiology procedures: portable C-arm vs. a new generation fluoroscopy system
K V Pierce1, B A Scansen1, S Rao1
1Department of Clinical Sciences, Colorado State University, Fort Collins, CO 80523, USA.
Introduction:
Occupational exposure to ionizing radiation poses health risks for veterinary interventionalists. There are limited veterinary studies evaluating radiation dose in the cardiac catheterization laboratory. The purpose of this study was to report direct radiation dose exposure to patients during common interventional cardiology procedures and compare these doses between two fluoroscopy units.
Animals:
One hundred and fifty-four client-owned dogs.
Materials And Methods:
Patient dose during procedures using a portable C-arm were retrospectively analyzed and compared to those performed in a contemporary interventional suite. Fluoroscopy equipment, procedure type, operator, patient weight, fluoroscopy time, dose area product, and air kerma were recorded and statistically modeled using univariable and multivariable linear regression to evaluate the effect of each factor.
Results:
Patient dose population (154 dogs), comprised 61 patent ductus arteriosus occlusions, 60 balloon pulmonary valvuloplasties, and 33 pacemaker implantations. Patient dose was significantly lower in the group utilizing a newer generation fluoroscopy unit vs. the group utilizing an older portable C-arm, positively correlated with patient weight, and highest during balloon pulmonary valvuloplasties compared to patent ductus arteriosus occlusions or pacemaker implantations (all P<0.010).
Discussion:
Newer fluoroscopy systems can be equipped with technologies that improve image quality while reducing patient dose and radiation exposure to interventional personnel.
Conclusions:
We documented a significant reduction in patient radiation dose using a newer fluoroscopy system as compared to an older portable C-arm for interventional cardiology procedures in animals. Improved knowledge of patient radiation dose factors may promote better radiation safety protocols in veterinary interventional cardiology.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
X-ray Imaging
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...