Relation of digital arterial dysfunction to alternative frequency weightings of hand-transmitted vibration
Massimo Bovenzi1, Marco Tarabini2
1Clinical Unit of Occupational Medicine, Department of Medical Sciences, University of Trieste, Italy.
Abstract:
This study compared the relative performance of alternative frequency weightings of hand-transmitted vibration (HTV) to predict the extent of cold-induced vasoconstriction in the digital arteries of HTV workers. The cold response of digital arteries was related to measures of daily vibration exposure expressed in terms of r.m.s. acceleration magnitude normalised to an 8-h day, frequency weighted according to either the frequency weighting Wh defined in international standard ISO 5349-1:2001 (Ah(8) in ms-2 r.m.s.) or the hand-arm vascular frequency weighting Wp proposed in the ISO Technical Report 18570:2007 (Ap(8) in ms-2 r.m.s.). The measure of daily vibration exposure constructed with the frequency weighting Wp (Ap(8)) was a better predictor of the cold response of the digital arteries in the HTV workers than the metric derived from the conventional ISO frequency weighting Wh (Ah(8)). This finding suggests that a measure of daily vibration exposure constructed with the vascular weighting Wp, which gives more weight to intermediate- and high-frequency vibration (31.5-250 Hz), performed better for the prediction of cold induced digital arterial hyperresponsiveness than that obtained with the frequency weighting Wh recommended in ISO 5349-1 which gives more importance to lower frequency vibration (≤16 Hz).
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pulse
The pulse serves as a clinical...