Related Experiment Video
Updated: Jul 30, 2025

An Isolated Working Heart System for Large Animal Models
Published on: June 11, 2014
Mock circulatory loop generated database for dynamic characterization of pressure-based cardiac output monitoring
Masoud Farahmand1, Erika Bodwell2, Gavin A D'Souza1
1Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, U.S. Food and Drug Administration, Silver Spring, MD, USA.
Abstract:
Pulse contour cardiac output monitoring systems allow real-time and continuous estimation of hemodynamic variables such as cardiac output (CO) and stroke volume variation (SVV) by analysis of arterial blood pressure waveforms. However, evaluating the performance of CO monitoring systems to measure the small variations in these variables sometimes used to guide fluid therapy is a challenge due to limitations in clinical reference methods. We developed a non-clinical database as a tool for assessing the dynamic attributes of pressure-based CO monitoring systems, including CO response time and CO and SVV resolutions. We developed a mock circulation loop (MCL) that can simulate rapid changes in different parameters, such as CO and SVV. The MCL was configured to simulate three different states (normovolemic, cardiogenic shock, and hyperdynamic) representing a range of flow and pressure conditions. For each state, we simulated stepwise changes in the MCL flow and collected datasets for characterizing pressure-based CO systems. Nine datasets were generated that contain hours of peripheral pressure, central flow and pressure waveforms. The MCL-generated database is provided open access as a tool for evaluating dynamic characteristics of pressure-based CO algorithms and systems in detecting variations in CO and SVV indices. In an example application of the database, a CO response time of 10 s, CO and SVV resolutions with lower and upper limits of (-9.1%, 8.4%) and (-5.0%, 3.8%), respectively, were determined for a pressure-based CO benchtop system. This tool will support a more comprehensive assessment of pressure-based CO monitoring systems and algorithms.
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...