Related Experiment Video
Updated: Jul 30, 2025

Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
Published on: June 8, 2017
Validity of a new sport-specific endurance test in artistic gymnastics
Bessem Mkaouer1, Samiha Amara1,2, Raja Bouguezzi3
1Department of Individual Sports, High Institute of Sport and Physical Education of Ksar Said, Manouba University, Tunis, Tunisia.
Introduction:
General and particularly sport-specific testing is an integral aspect of performance optimization in artistic gymnastics. In artistic gymnastics, however, only non-specific field tests have been used to assess endurance performance (e.g., Multistage Shuttle Run Test; Cooper's Test).
Methods:
This study aimed to examine the validity of a new sport-specific endurance test in artistic gymnastics. Fourteen elite-level gymnasts (i.e., eight males and six females) participated in this study. The newly developed artistic gymnastics-specific endurance test (AGSET) was conducted on two different occasions seven days apart to determine its reliability. To assess the concurrent validity of AGSET, participants performed the multistage shuttle run test (MSRT). Maximum oxygen uptake (VO2max) and respiratory exchange ratio (RER) were directly assessed using a portable gas analyzer system during both protocols. Additionally, the total time maintained (TTM) during the AGSET, maximum heart rate (HRmax), maximal aerobic speed (MAS), and blood lactate concentration (BLa) during the two protocols were collected.
Results:
The main findings indicated that all variables derived from the AGSET (i.e., VO2max, MAS, HRmax, BLa, and RER) displayed very good relative (all intraclass correlation coefficients [ICC] > 0.90) and absolute (all typical errors of measurement [TEM] < 5%) reliability. Further, results showed that the ability of the AGSET to detect small changes in VO2max, MAS, BLa, and RER was good (smallest worthwhile change [SWC0.2] > TEM), except HRmax (SWC0.2 < TEM). Additionally, results showed a nearly perfect association between the VO2max values derived from the AGSET and MSRT (r = 0.985; coefficient of determination [R²] = 97%) with no statistically significant differences (p>0.05). The mean (bias) ± 95% limits of agreement between the two protocols were 0.28 ± 0.55 mlminkg-1.
Discussion:
AGSET seems to present very good reliability and concurrent validity for assessing endurance performance in elite artistic gymnastics. In addition, the newly developed protocol presents a good ability to detect small changes in performance.
More Related Videos
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...