Related Experiment Video
Updated: Jul 30, 2025

Author Spotlight: Enhancing Fiber Composite Laminate Quality with the Wet Hand Lay-Up/Vacuum Bag Process
Published on: June 30, 2023
Performance Analysis of Loose-Fill Thermal Insulation from Wood Scobs Coated with Liquid Glass, Tung Oil, and
Nerijus Augaitis1, Jurga Šeputytė-Jucikė1, Sylwia Członka2
1Laboratory of Thermal Insulating Materials and Acoustics, Institute of Building Materials, Faculty of Civil Engineering, Vilnius Gediminas Technical University, Linkmenų st. 28, LT-08217 Vilnius, Lithuania.
Abstract:
The current study presents the results of monitoring the behavior of loose-fill thermal insulating material for buildings made of wood scobs (WS), which were coated with one, two, and three component-based coatings from liquid glass (LG), tung oil (TO), and expandable graphite (EG). The thermal conductivity of samples in the dry state and under normal laboratory conditions, short-term water absorption by partial immersion, surface wettability, and water vapor permeability were evaluated, and regression equations describing the variations in numerical values of specified properties under different amounts of each coating component were presented. It was shown that LG and TO act as hydrophobic layers that, in conjunction, reduce water absorption by a maximum of 274%, have a contact angle equal to 86°, and lower thermal conductivity by 55% in the dry state due to the specifics of the layer formed on the surface of WS. The addition of EG to LG coating resulted in insignificantly changed water absorption and thermal conductivity values, indicating the potential of this material to be used to improve the fire resistance of wood-based composites in the future. The results showed that the three-component layer of LG/TO/EG reduces water absorption by a maximum of 72%, increases thermal conductivity in the dry state by a minimum of 0.4%, and increases the contact angle to 81° at 100 wt.% LG. The changes in water vapor permeability of all compositions were determined to be insignificant.
More Related Videos
10:29Experimental Methodology for Estimation of Local Heat Fluxes and Burning Rates in Steady Laminar Boundary Layer Diffusion Flames
Published on: June 1, 2016
09:06The Effect of Construction and Demolition Waste Plastic Fractions on Wood-Polymer Composite Properties
Published on: June 7, 2020
Related Concept Videos
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Insulation Coordination
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
Thermal Expansion
Measurement of Air Content in Concrete
The pressure method,...
Masonry Cavity Walls
Maintaining a clean cavity during construction...