Related Experiment Video
Updated: Jul 30, 2025

Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
An Online Monitoring Method for Low-Frequency Dielectric Loss Angle of Mining Cables
Yanwen Wang1, Peng Chen1, Chen Feng2
1School of Mechanical, Electronic & Information Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China.
Abstract:
The dielectric loss angle can better reflect the overall insulation level of mining cables, so it is necessary to implement reliable and effective online monitoring of the dielectric loss angle of mining cables. In order to improve the monitoring accuracy of the dielectric loss angle tan δ of mining cables, a low-frequency dielectric loss angle online monitoring method combining signal injection method and double-end synchronous measurement method is proposed in this paper. Firstly, the superiority of the low-frequency signal in improving the detection accuracy of dielectric loss angle is explained, and the feasibility of the low-frequency signal injection method is analyzed. Secondly, the cable leakage is calculated using the double-terminal synchronous measurement method to measure the core current at the first and last ends of the cable, and the phase sum of the voltage at the first and last ends is selected as the reference phase quantity to realize the effective calculation of the dielectric loss angle tan δ of the cable. Then, the simulation model for online monitoring of dielectric loss angle of mining cable is built, and the feasibility of the online monitoring method proposed in this paper is verified by combining the simulation results. Finally, the theoretical and simulation analysis of the monitoring error of dielectric loss angle of mining cable is carried out.
More Related Videos
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
09:36Continuous-Wave Propagation Channel-Sounding Measurement System - Testing, Verification, and Measurements
Published on: June 25, 2021
Related Concept Videos
Lossy Lines and Overvoltages
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
Energy Stored In A Coaxial Cable
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic...
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Lossless Lines
Resistance and Conductance
Various factors impact the resistance of a conductor. Spiraling in stranded conductors increases their...