Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

4.7K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
4.7K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

30
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
30
Pharmacokinetic Models: Comparison and Selection Criterion01:26

Pharmacokinetic Models: Comparison and Selection Criterion

115
Physiological and compartmental models are valuable tools used in studying biological systems. These models rely on differential equations to maintain mass balance within the system, ensuring an accurate representation of the dynamic processes at play.
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
115
Positron Emission Tomography01:29

Positron Emission Tomography

4.3K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
4.3K
Mechanistic Models: Compartment Models in Individual and Population Analysis01:23

Mechanistic Models: Compartment Models in Individual and Population Analysis

68
Mechanistic models are utilized in individual analysis using single-source data, but imperfections arise due to data collection errors, preventing perfect prediction of observed data. The mathematical equation involves known values (Xi), observed concentrations (Ci), measurement errors (εi), model parameters (ϕj), and the related function (ƒi) for i number of values. Different least-squares metrics quantify differences between predicted and observed values. The ordinary least...
68
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

182
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
182

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Evaluation of CT dose-averaged detectability: a repeatability study.

Zeitschrift fur medizinische Physik·2026
Same author

Biokinetic modelling of the exhalation of <sup>219</sup>Rn gas and its airborne progeny from patients undergoing treatment with <sup>223</sup>Ra-dichloride and effective dose estimation for caregivers.

Radiation and environmental biophysics·2026
Same author

Reference Levels for Diagnostic and Interventional X-ray Exposures in Germany: Development, Handling, and Perspective.

RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin·2026
Same author

International survey in four European countries on diagnostic reference levels based on clinical indications in computed tomography.

Insights into imaging·2026
Same author

European radiation protection week 2025-meeting summary.

Journal of radiological protection : official journal of the Society for Radiological Protection·2026
Same author

Correction: Requirements for Physico-Technical Quality Assurance in the Framework of Early Detection of Lung Cancer.

RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin·2026
Same journal

Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

Medical physics·2026
Same journal

Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

Medical physics·2026
Same journal

A novel optical respiratory gating system with a hybrid phase-amplitude algorithm for spot-scanning proton therapy.

Medical physics·2026
Same journal

Gamma Knife treatment planning using knowledge-based reinforcement learning.

Medical physics·2026
Same journal

Development and characterization of a novel, small animal external beam irradiator using a clinical high dose rate brachytherapy source.

Medical physics·2026
Same journal

Deep learning-based dose prediction for MR-guided prostate SIB: Supporting rapid feasibility assessment and adaptive editing margin selection.

Medical physics·2026
See all related articles

Related Experiment Video

Updated: Jul 30, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
08:30

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

Published on: September 11, 2011

14.5K

Dose-efficiency quantification of computed tomography systems using a model-observer.

Maximilian Göppel1, Mathias Anton2, Hugo de Las Heras Gala1

  • 1Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Neuherberg, Germany.

Medical Physics
|May 15, 2023
PubMed
Summary
This summary is machine-generated.

A new weighted detectability figure of merit (FOM) objectively benchmarks computed tomography (CT) systems and reconstruction algorithms. This approach provides uncertainties, enabling robust type testing for dose efficiency.

Keywords:
regulatory issuestask-based image-quality assessmentx-ray CT

More Related Videos

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
12:24

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers

Published on: July 17, 2012

12.4K
Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
07:31

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator

Published on: May 9, 2014

11.9K

Related Experiment Videos

Last Updated: Jul 30, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
08:30

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

Published on: September 11, 2011

14.5K
Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
12:24

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers

Published on: July 17, 2012

12.4K
Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
07:31

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator

Published on: May 9, 2014

11.9K

Area of Science:

  • Medical Imaging Physics
  • Radiological Technology
  • Image Analysis

Background:

  • Computed tomography (CT) technology has advanced, improving image quality and reducing radiation dose.
  • A standardized figure of merit (FOM) is lacking for comparing CT system dose efficiencies.

Purpose of the Study:

  • Establish a mathematical model observer-based FOM for CT image quality relative to radiation dose.
  • Evaluate the proposed FOM across diverse CT systems and reconstruction algorithms.

Main Methods:

  • Acquired phantom images using three CT systems at varying doses and abdominal protocols.
  • Reconstructed images with filtered-back projection and iterative algorithms.
  • Applied a channelized Hotelling observer to compute detectability, averaging results for robustness.

Main Results:

  • Detectability varied significantly with insert characteristics, radiation dose, and reconstruction methods.
  • A single detectability value is insufficient for comprehensive dose efficiency characterization.
  • Averaged detectabilities, particularly weighted detectability ( ), provided a more robust assessment.

Conclusions:

  • An automatable software approach using weighted detectability ( ) offers an objective FOM for benchmarking CT systems.
  • The model-observer approach provides crucial uncertainty information for type testing.
  • This method enables robust and reliable comparison of CT systems and reconstruction algorithms.