Related Experiment Video
Updated: Jul 29, 2025

Accurate Determination of the Equilibrium Surface Tension Values with Area Perturbation Tests
Published on: August 30, 2019
The Surface Tension of Synthetic Blood used for ASTM F1670 Penetration Tests
Lee Portnoff1, Peter A Jaques2, Jennifer L Furlong1
1Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health (NIOSH), National Personal Protective Technology Laboratory (NPPTL), 626 Cochrans Mill Road, Pittsburgh, Pennsylvania 15236.
Abstract:
The American Society for Testing and Material (ASTM International) F1670 test method was based on research involving transmission of bloodborne pathogens (Hepatitis B, Hepatitis C, and HIV) in the 1980s. The test method details the measurement of synthetic blood penetration through garments. A key parameter affecting penetration is synthetic blood surface tension which is measured via du Noüy ring tensiometer. However, little is known about the sources of variation impacting surface tension measurements. In this study, the synthetic blood used for ASTM F1670 was evaluated from within the ASTM F903 test apparatus and with two mixing treatments. Measurements were compared against two outside laboratories and with two alternate tensiometric methods (pendant drop and capillary rise). It was found that using the methods specified in the ASTM F1670 test method, surface tension of the synthetic blood was not 40-44 dynes/cm as was expected. The surface tension was initially above 50 dynes/cm and declined to below 40 dynes/cm after 60 minutes. The surface tension within the penetration cell was relatively constant over time, showing that the surface tension measurements outside the penetration cell are not indicative of the surface tension within the apparatus during the test. Shaking the synthetic blood, a mixing procedure detailed in the ASTM F1670 test method, increased the surface tension. The increase was greatest in a container having more airspace. Du Noüy ring measurements by NIOSH compared to external labs were within 15%. Testing with alternate methods showed that the "open-to-atmosphere" methods (ring and drop) began lower and declined rapidly when compared to the "closed-to-atmosphere" method (capillary). Results of this research will help amend the ASTM F1670 standard to better characterize the measurement and handling of synthetic blood used in the ASTM F1670 test and to provide a framework for consideration of test fluid used in future ASTM standards.
Related Concept Videos
Surface Tension of Fluid
Surface tension varies...
Testing Water Quality
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Flow Table Test
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...

