Evaluating the Effect of Timing on Point-of-Care Testing of INR
Joanne Son1,2, Elise M Kim3
1Department of Pharmacy Practice, Touro College of Pharmacy, New York, NY, USA.
Abstract:
Objectives: To evaluate if there is a difference in International Normalized Ratio (INR) readings taken within the 15 second time frame after lancing the finger vs 30-60 seconds of obtaining a blood drop utilizing a CoaguChek® XS Plus point-of-care (POC) INR machine in patients on warfarin therapy. Methods: All adult patients on anticoagulation therapy with warfarin who were managed in a pharmacist-run anticoagulation clinic were considered for inclusion in the study. The mean difference of INR readings taken less than 15 seconds vs between 30-60 seconds after the blood drop was obtained from the finger was assessed. Results: A total of 62 pairs of INR results were included in the study. There was a mean difference in INR of .076 (95% CI 0.011-.140; P = .0217) when comparing INR readings taken less than 15 seconds and between 30-60 seconds after the blood drop was obtained from the finger. Conclusions: There was a significant difference in INR readings taken less than 15 seconds vs 30-60 seconds after obtaining the blood drop when utilizing a POC INR machine. INR readings taken 30-60 seconds after obtaining a blood drop with the CoaguChek® XS Plus POC INR machine is not acceptable for use to monitor patients on warfarin.
Related Concept Videos
Chronopharmacokinetics: Circadian Rhythms and Influence on Drug Response
The time of drug administration is an important factor to consider, as it can influence the toxic dose of a drug. For example, a study conducted by Prins et al. in 1997 examined the effects of the timing of...
Time Course of Drug Effect
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Chronopharmacokinetics: Time-Dependent Pharmacokinetics
Time-dependent pharmacokinetics refers to non-cyclical changes in drug rate processes over a period of time. It can lead to nonlinear pharmacokinetics, where the relationship between drug concentration and time is not proportional. Non-cyclical...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.