Related Experiment Video
Updated: Jul 29, 2025

Echocardiographic Assessment Using Subxiphoid-Only Examination for Hypotensive Patients
Published on: April 18, 2025
DEVELOPMENT OF SCORE SYSTEM BASED ON POINT-OF-CARE ULTRASOUND TO PREDICT VASOPRESSOR REQUIREMENT FOR EMERGENCY
Hayoung Kim1, Yun Seong Park1, Jin Hee Kim
1Department of Emergency Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Abstract:
Objectives : Patients with cardiopulmonary symptoms admitted to the emergency department (ED) have high mortality and intensive care unit admission rates. We developed a new scoring system comprising concise triage information, point-of-care ultrasound, and lactate levels to predict vasopressor requirements. Methods : This retrospective observational study was conducted at a tertiary academic hospital. Patients with cardiopulmonary symptoms who visited the ED and underwent point-of-care ultrasound between January 2018 and December 2021 were enrolled. The influence of demographic and clinical findings on the requirement for vasopressor support within 24 h of ED admission was investigated. A new scoring system was developed using key components after stepwise multivariable logistic regression analysis. Prediction performance was evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Results : A total of 2,057 patients were analyzed. A stepwise multivariable logistic regression model showed high predictive performance in the validation cohort (AUC, 0.87). Eight key components were selected: hypotension, chief complaint, and fever at ED admission, and way of ED visit, systolic dysfunction, regional wall motion abnormalities, inferior vena cava status, and serum lactate level. The scoring system was developed based on the β coefficients of each component: accuracy, 0.8079; sensitivity, 0.8057; specificity, 0.8214; PPV, 0.9658; and NPV, 0.4035, with a cutoff value according to the Youden index. Conclusions : A new scoring system was developed to predict vasopressor requirements in adult ED patients with cardiopulmonary symptoms. This system can serve as a decision-support tool to guide efficient assignment of emergency medical resources.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiopulmonary Resuscitation IV: Pharmacological Management
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiomyopathy VII: Pre and Post Operative Nursing Management

