Related Experiment Video
Updated: Jul 29, 2025

A Fluorescence-based Lymphocyte Assay Suitable for High-throughput Screening of Small Molecules
Published on: March 10, 2017
Orthogonal Combinatorial Raman Codes Enable Rapid High-Throughput-Out Library Screening of Cell-Targeting Ligands
Yuchen Tang1, Xingxing Zheng1, Tingjuan Gao1
1China Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, College of Chemistry, Central China Normal University, Wuhan 430079, China.
Abstract:
High-throughput assays play an important role in the fields of drug discovery, genetic analysis, and clinical diagnostics. Although super-capacity coding strategies may facilitate labeling and detecting large numbers of targets in a single assay, practically, the constructed large-capacity codes have to be decoded with complicated procedures or are lack of survivability under the required reaction conditions. This challenge results in either inaccurate or insufficient decoding outputs. Here, we identified chemical-resistant Raman compounds to build a combinatorial coding system for the high-throughput screening of cell-targeting ligands from a focused 8-mer cyclic peptide library. The accurate in situ decoding results proved the signal, synthetic, and functional orthogonality for this Raman coding strategy. The orthogonal Raman codes allowed for a rapid identification of 63 positive hits at one time, evidencing a high-throughput-out capability in the screening process. We anticipate this orthogonal Raman coding strategy being generalized to enable efficient high-throughput-out screening of more useful ligands for cell targeting and drug discovery.