Assessment of Neuromuscular Function Using Percutaneous Electrical Nerve Stimulation
Published on: September 13, 2015
Myoelectric activity during electromagnetic resistance alone and in combination with variable resistance or eccentric
Hugo Zambrano1, Xavier Torres1, Max Coleman1
1Department of Exercise Science and Recreation, CUNY Lehman College, Bronx, NY, USA.
This study compared electromagnetic resistance devices to traditional dumbbells for elbow flexion exercises. While electromagnetic devices showed slightly higher muscle activation in the anterior deltoid, overall differences were minimal and likely not practically significant for resistance training.
Area of Science:
- Biomechanics
- Exercise Physiology
- Human Movement Science
Background:
- Understanding muscle activation patterns is crucial for optimizing resistance training programs.
- Various resistance modalities exist, each with unique force-velocity characteristics.
- Comparing novel electromagnetic resistance devices to traditional methods is essential for practical application.
Purpose of the Study:
- To compare the myoelectric activity of elbow flexor muscles during resistance exercise using electromagnetic resistance versus traditional dynamic constant external resistance.
- To investigate the effects of variable resistance and eccentric overload settings on muscle activation.
- To determine the practical significance of observed differences in muscle activation.
Main Methods:
- A within-participant randomized cross-over design was used with 16 resistance-trained individuals.
- Participants performed elbow flexion using dumbbells (DB), an electromagnetic device (ELECTRO), variable resistance (VR), and eccentric overload (EO) at a 10-repetition maximum.
- Surface electromyography (sEMG) of the biceps brachii, brachioradialis, and anterior deltoid was recorded and synchronized with motion capture.
Main Results:
- The anterior deltoid exhibited greater concentric sEMG amplitude (7-10%) with EO, ELECTRO, and VR compared to DB.
- Biceps brachii concentric sEMG amplitude was similar across all conditions.
- Dumbbell exercise showed greater eccentric brachioradialis sEMG amplitude compared to the electromagnetic device, though differences were modest (<5%).
Conclusions:
- Electromagnetic resistance devices may offer slight advantages in anterior deltoid activation compared to dumbbells.
- Observed differences in muscle activation between electromagnetic devices and dumbbells were generally modest (<10%) and likely of minimal practical significance.
- Further research could explore long-term training adaptations with different resistance modalities.
Related Concept Videos
Design Example: Frog Muscle Response
When the switch connecting the RL circuit is closed, a brief muscle contraction is observed. This is because, at a steady state, the inductor acts like a short...
Motor Unit Stimulation
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Generation of Action Potential in Skeletal Muscles
Like neurons, muscle cells are also regarded as excitable due to their capacity to change in response to stimuli, primarily due to voltage-gated ion channels embedded in their plasma membranes, which get activated by alterations in the...
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...
Motional Emf