Related Experiment Video
Updated: Jul 29, 2025

Photochemical Oxidative Growth of Iridium Oxide Nanoparticles on CdSe@CdS Nanorods
Published on: February 11, 2016
Development of a Primary Iridium Solution Standard Traceable to the International System of Units
Madeline Gozzi1, Paul Gaines1, Thomas Kozikowski1
1Inorganic Ventures, 300 Technology Drive, Christiansburg, Virginia 24073, United States.
Abstract:
The purpose of this work was to develop a primary solution standard for iridium (Ir) that is directly traceable to the International System of Units (SI). The candidate starting material was ammonium hexachloroiridate hydrate, ((NH4)3IrCl6·3H2O), the Ir salt. The SI traceability of the Ir salt was established by the gravimetric reduction (GR) of the salt to the metal under H2. GR traces the results of the analysis directly to the SI base unit of mass, the kg. The GR was also performed on high-purity Ir metal powder, an independent source of Ir, used as a comparison material for the salt. A method for dissolving the Ir metal was developed by modifying information found in the literature. Trace metallic impurities (TMI) analysis was performed on the Ir salt using ICP-OES and ICP-MS. Inert gas fusion (IGF) analysis provided data for the O, N, and H content of the gravimetrically reduced and unreduced Ir metals. The combined results of the TMI and IGF analyses provided the purity data, a required component for the claim to SI traceability. Solution standards were gravimetrically prepared from the candidate SI traceable Ir salt. Solution standards for comparison were prepared from the dissolved, unreduced high-purity Ir metal powder. These solutions were compared by a high-precision ICP-OES method. Agreement in the results between these Ir solutions, with uncertainty estimates calculated by error budget analysis, confirmed the accuracy of the Ir assay in the candidate SI traceable Ir salt, (NH4)3IrCl6·3H2O, thus confirming the concentrations and uncertainties for the primary SI traceable Ir solution standards made from the (NH4)3IrCl6·3H2O.
More Related Videos
12:52IridiumIII Luminescent Probe for Detection of the Malarial Protein Biomarker Histidine Rich Protein-II
Published on: July 7, 2015
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry CE-ICP-MS for Quantification of Iron Redox Species FeII, FeIII
Published on: May 4, 2020
Related Concept Videos
Standard Solutions
Redox Titration: Iodimetry and Iodometry
SI Units: 2019 Redefinition
A standard set of units has been defined...
Precipitation Titration Curve: Analysis
Expressing Solution Concentration
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.
International System of Units
Prefixes are used to define both larger and smaller quantities in the SI system. For example, milli, micro, and nano define smaller quantities, while kilo, mega, and giga are used to define...